Systematic meta-review: diagnostic accuracy of colon capsule endoscopy for colonic neoplasia with umbrella meta-analysis
Therapeutic Advances in Gastrointestinal Endoscopy · 2025-08 · 18
DOI: 10.1177/26317745251370845 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Therapeutic Advances in Gastrointestinal Endoscopy, online erschienen am 30.08.2025. Verfasst von Ian Io Lei und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Precision Diagnostics & Translational Medicine, University Hospital of Coventry and Warwickshire, Clifford Bridge Rd, Coventry CV2 2DX, …. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Colorectal cancer (CRC) incidence is rising globally, intensifying pressure on endoscopy services. Colon capsule endoscopy (CCE) offers a non-invasive alternative. Despite several systematic reviews showing reasonable polyp detection rates, clinical scepticism remains.
Objectives
This meta-review and umbrella meta-analysis aim to synthesise evidence on CCE’s diagnostic accuracy in polyp and CRC detection, using CT colonography or colonoscopy as the reference standard.
Methods
We conducted a systematic search of EMBASE, MEDLINE and PubMed for systematic reviews evaluating the diagnostic accuracy of CCE in detecting polyps and CRC. A qualitative thematic review and synthesis were conducted following PRISMA guidelines. A bivariate generalised linear mixed model with random effects was used for pooled diagnostic accuracy estimates, and meta-regression was performed using restricted maximum likelihood estimation.
Results
Nine systematic reviews encompassing 28 unique studies (3472 participants) were included. For polyps of any size, the pooled per-patient sensitivity was 0.79 (95% CI: 0.69–0.86), specificity was 0.77 (95% CI: 0.71–0.82), and the area under the curve (AUC) was 0.81. For polyps ⩾6 mm, sensitivity and specificity were 0.80 and 0.87 (AUC 0.81), and for polyps ⩾10 mm, 0.88 and 0.95 (AUC 0.95), respectively. Second-generation CCE (CCE2) improved diagnostic accuracy across all polyp sizes. For polyps of any size, CCE2 achieved a sensitivity of 0.90, specificity of 0.81 and AUC of 0.82. For polyps ⩾ 6 mm and ⩾10 mm, AUCs were 0.92 and 0.94, respectively. CCE2 showed high sensitivity for detecting any polyp size and polyps ⩾6 mm, with low heterogeneity ( p > 0.05, I 2 < 25%). CRC detection sensitivity was 0.96 (95% CI: 0.73–1.00) after excluding cases where the capsule failed to reach the rectum due to battery exhaustion.
Conclusion
CCE2 has high diagnostic accuracy for polyps and colorectal cancer detection. While technical challenges persist, CCE2 shows promise as a complementary diagnostic tool to help address the increasing demands for endoscopy services.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Precision Diagnostics & Translational Medicine, University Hospital of Coventry and Warwickshire, Clifford Bridge Rd, Coventry CV2 2DX, UK.
- Warwick Medical School, University of Warwick, Coventry, UK.
- Gastroenterology and Endoscopy Unit, University Hospital of Parma, University of Parma, Parma, Italy.
- Department of Gastroenterology, Pomeranian Medical University in Szczecin, Szczecin, West Pomeranian Voivodeship, Poland.
- Department of Biochemical Science, Pomeranian Medical University in Szczecin, Szczecin, West Pomeranian Voivodeship, Poland.
- Institute of Precision Diagnostics & Translational Medicine, University Hospital of Coventry and Warwickshire, Coventry, UK.
ORCID-Profile: Ian Io Lei, Pablo Cortegoso Valdivia, Wojciech Marlicz, Anastasios Koulaouzidis
Zitieren
APA
Lei, I. I., Cortegoso Valdivia, P., Marlicz, W., Skonieczna-Żydecka, K., Arasaradnam, R., Eliakim, R., & Koulaouzidis, A. (2025). Systematic meta-review: diagnostic accuracy of colon capsule endoscopy for colonic neoplasia with umbrella meta-analysis. Therapeutic Advances in Gastrointestinal Endoscopy, 18. https://doi.org/10.1177/26317745251370845
Vancouver
Lei II, Cortegoso Valdivia P, Marlicz W, Skonieczna-Żydecka K, Arasaradnam R, Eliakim R, et al. Systematic meta-review: diagnostic accuracy of colon capsule endoscopy for colonic neoplasia with umbrella meta-analysis. Therapeutic Advances in Gastrointestinal Endoscopy. 2025;18. doi:10.1177/26317745251370845
BibTeX
@article{Lei2025,
author = {Lei, Ian Io and Cortegoso Valdivia, Pablo and Marlicz, Wojciech and Skonieczna-Żydecka, Karolina and Arasaradnam, Ramesh and Eliakim, Rami and Koulaouzidis, Anastasios},
title = {Systematic meta-review: diagnostic accuracy of colon capsule endoscopy for colonic neoplasia with umbrella meta-analysis},
journal = {Therapeutic Advances in Gastrointestinal Endoscopy},
year = {2025},
volume = {18},
doi = {10.1177/26317745251370845}
}
EUVIMED