Point-of-care ultrasound of the common carotid arteries for detection of large vessel occlusion stroke: Results of the POCUS-LVO study

Point-of-care-Ultraschall der Arteria carotis communis zum Nachweis eines Large-Vessel-Occlusion-Schlaganfalls: Ergebnisse der POCUS-LVO-Studie

João Pinho iD, Anna Tyurina, Celina Hartmann, Omar Abu Audeh, Pardes Habib iD, Ramy Abdelnaby iD, Oliver Matz, Marc Felzen, Jörg C Brokmann, Martin Wiesmann, Jörg B Schulz iD, Omid Nikoubashman und 1 weitere

European Stroke Journal · 01.09.2025 · 10 (3) · 853-861

DOI: 10.1177/23969873251315337 ↗

Auf einen Blick

Bei 257 Patient:innen mit Schlaganfallsuspekt zeigte der POCUS der Arteria carotis communis eine hohe diagnostische Genauigkeit für ac-LVO. Am besten schnitt die enddiastolische Geschwindigkeitsdifferenz zwischen beiden Seiten ab.

Fragestellung

Wie genau erkennt POCUS der Arteria carotis communis bei Patient:innen mit Verdacht auf Schlaganfall einen anterioren Large-Vessel-Occlusion (ac-LVO)?

Methode

Prospektive, monozentrische Beobachtungsstudie bei erwachsenen Patient:innen in der Notaufnahme; POCUS beider CCA durch Nichtfachkräfte; ac-LVO per CT-/MR-Angiographie definiert.

Ergebnisse

283 Patient:innen rekrutiert, 257 in der Analyse. ac-LVO bei 30 Patient:innen (11,9 %). Beste diagnostische Leistung: enddiastolische Geschwindigkeitsdifferenz zwischen den Seiten, AUC 0,90 (95 %-KI 0,85–0,93); Spezifität 83 % (95 %-KI 78–88 %) bei 80 % Sensitivität.

Einschränkungen

Ein einzelnes Zentrum; die Ergebnisse müssen in einem prähospitalen Setting repliziert werden.

Schlussfolgerung der Autor:innen

POCUS der CCA bei Patient:innen mit Schlaganfallverdacht kann das Vorliegen eines ac-LVO vorhersagen.

Kernaussagen

  • 257 auswertbare POCUS-Untersuchungen
  • ac-LVO bei 30 Patient:innen (11,9 %)
  • AUC 0,90; Spezifität 83 % bei 80 % Sensitivität

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Beobachtungsstudie in der Zeitschrift European Stroke Journal, online erschienen am 01.09.2025. Verfasst von João Pinho und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University Hospital RWTH Aachen, Aachen, Germany. Hauptthemen laut MEDLINE: Point-of-Care Systems, Carotid Artery, Common, Stroke, Ischemic Stroke. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Fakultät, RWTH Aachen University.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Distal arterial occlusions can cause measurable changes in the flow wave profile in proximal segments of the feeding artery. Our objective was to study the diagnostic accuracy of point-of-care ultrasound (POCUS) of the common carotid arteries (CCA) for detection of anterior circulation large vessel occlusion (ac-LVO) in patients with suspected stroke. Patients and methods We conducted a prospective, single-center, observational study of adult patients with suspected stroke admitted in the emergency department. Flow wave profiles of both CCAs were generated by non-specialists using POCUS as soon as possible after admission. ac-LVO was defined as an internal carotid artery or M1 occlusion in CT- or MR-angiography. The diagnostic performances for detection of ac-LVO using flow wave parameters were calculated.

Results

Among 283 patients recruited during a 10-month period, 257 patients (91%) had CCA ultrasound images of sufficient quality and were included for analysis. The mean age was 75 years (IQR 62–83), 131 were female (51.0%), median baseline NIHSS was 2 (IQR 0–5). The most frequent final diagnosis was ischemic stroke (49.4%), ac-LVO was present in 30 patients (11.9%). The median duration of POCUS was 3 min (IQR 2–5). Among all flow wave parameters, the highest diagnostic accuracy for ac-LVO detection was found for end-diastolic velocity difference between sides (AUC = 0.90, 95%CI = 0.85–0.93), with a specificity of 83% (95%CI = 78–88%) at a predefined sensitivity threshold of 80%. Discussion and conclusion POCUS of the CCA in patients with suspected stroke can predict the presence of ac-LVO. These results need to be replicated in a prehospital setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Point-of-Care SystemsCarotid Artery, CommonStrokeIschemic StrokeHumansFemaleMaleAgedMiddle AgedProspective StudiesUltrasonographyAged, 80 and over

Stichwörter der Autor:innen

Strokelarge vessel occlusionmechanical thrombectomysensitivity and specificityultrasound

Autor:innen und Institutionen

  • Department of Neurology, University Hospital RWTH Aachen, Aachen, Germany.
  • Department of Neurosurgery, School of Medicine, Stanford University, Stanford, USA.
  • Department of Anesthesiology, University Hospital RWTH Aachen, Aachen, Germany.
  • Emergency Department, University Hospital RWTH Aachen, Aachen, Germany.
  • Department of Diagnostic and Interventional Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
  • JARA-BRAIN Institute Molecular Neuroscience and Neuroimaging, Forschungszentrum Jülich GmbH and RWTH Aachen University, Aachen, Germany.

ORCID-Profile: João Pinho, Pardes Habib, Ramy Abdelnaby, Jörg B Schulz, Arno Reich

Förderung

  • Medizinische Fakultät, RWTH Aachen University

Zitieren

APA

Pinho, J., Tyurina, A., Hartmann, C., Audeh, O. A., Habib, P., Abdelnaby, R., Matz, O., Felzen, M., Brokmann, J. C., Wiesmann, M., Schulz, J. B., Nikoubashman, O., & Reich, A. (2025). Point-of-care ultrasound of the common carotid arteries for detection of large vessel occlusion stroke: Results of the POCUS-LVO study. European Stroke Journal, 10(3), 853-861. https://doi.org/10.1177/23969873251315337

Vancouver

Pinho J, Tyurina A, Hartmann C, Audeh OA, Habib P, Abdelnaby R, et al. Point-of-care ultrasound of the common carotid arteries for detection of large vessel occlusion stroke: Results of the POCUS-LVO study. European Stroke Journal. 2025;10(3):853-861. doi:10.1177/23969873251315337

BibTeX
@article{Pinho2025,
  author = {Pinho, João and Tyurina, Anna and Hartmann, Celina and Audeh, Omar Abu and Habib, Pardes and Abdelnaby, Ramy and Matz, Oliver and Felzen, Marc and Brokmann, Jörg C and Wiesmann, Martin and Schulz, Jörg B and Nikoubashman, Omid and Reich, Arno},
  title = {Point-of-care ultrasound of the common carotid arteries for detection of large vessel occlusion stroke: Results of the POCUS-LVO study},
  journal = {European Stroke Journal},
  year = {2025},
  volume = {10},
  number = {3},
  pages = {853--861},
  doi = {10.1177/23969873251315337}
}
Kostenlos starten →