The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners
Trends in Hearing · 2026
DOI: 10.1177/23312165261486089 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Trends in Hearing, 2026. Verfasst von Caylin McCallick und 5 weiteren Autor:innen. Beteiligte Einrichtung: Massachusetts Eye and Ear, Harvard Medical School, Department of Otolaryngology Head and Neck Surgery, Boston, MA, USA. Hauptthemen laut MEDLINE: Cochlear Implants, Auditory Threshold, Cochlear Implantation, Deafness. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIDCD NIH HHS, NIH/NIDCD.
Abstract (Originalsprache)
Cochlear implants (CIs) are considered effective at restoring some hearing abilities to individuals with severe hearing loss. However, there is considerable variability in performance outcomes among adults with CIs. One likely source of variability is the quality of the electrode-neuron interface (ENI), which describes how well implanted electrodes stimulate nearby spiral-ganglion neurons (SGNs) in the cochlea. Absolute thresholds, measured via focused electrical stimulation, have been proposed as a behavioral estimate of ENI. In this retrospective study, focused-stimulation threshold patterns were compared for 92 ears from 74 adult cochlear implant listeners with various etiologies, durations of deafness, and electrode array types. The results showed that CI listeners implanted with a pre-curved array tended to have lower overall focused thresholds than listeners with straight arrays, as well as a threshold profile with lower (better) thresholds at each end of the array and highest thresholds near the middle of the array. CI listeners with etiologies related to auto-immune dysfunction, such as Meniere’s disease, tended to have the opposite profile, with lowest thresholds near the middle of the array. No significant effect of duration of deafness on focused thresholds was observed. Further investigation into which demographic and device factors affect focused thresholds, and therefore potentially ENI, could shed light on the variability of CI outcomes and guide development of individualized treatment strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Massachusetts Eye and Ear, Harvard Medical School, Department of Otolaryngology Head and Neck Surgery, Boston, MA, USA.
- Department of Psychology, University of Minnesota, Minneapolis, MN, USA.
ORCID-Profile: Caylin McCallick, Scott C Aker, Heather A Kreft, Andrew J Oxenham, Julie G Arenberg
Förderung
- NIDCD NIH HHS
- NIH/NIDCD
Zitieren
APA
McCallick, C., Aker, S. C., Kreft, H. A., Munjal, T., Oxenham, A. J., & Arenberg, J. G. (2026). The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners. Trends in Hearing. https://doi.org/10.1177/23312165261486089
Vancouver
McCallick C, Aker SC, Kreft HA, Munjal T, Oxenham AJ, Arenberg JG. The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners. Trends in Hearing. 2026. doi:10.1177/23312165261486089
BibTeX
@article{McCallick2026,
author = {McCallick, Caylin and Aker, Scott C and Kreft, Heather A and Munjal, Tina and Oxenham, Andrew J and Arenberg, Julie G},
title = {The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners},
journal = {Trends in Hearing},
year = {2026},
doi = {10.1177/23312165261486089}
}
EUVIMED