EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Auditory Differences in Occupationally Noise-Exposed Workers With Normal Conventional Audiograms: A Multi-Measure Surveillance Approach

Wulan Zhao, Alexis Pinsonnault-Skvarenina iD, Meibian Zhang, Zhili Zhang, Hangze Mao, Shixing Bai, Hua Zou, Dan Guo, Changyan Yu, Adrian Fuente, Wei Qiu iD

Trends in Hearing · 2026-01 · 30

DOI: 10.1177/23312165261477842 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Trends in Hearing, online erschienen am 07.08.2026. Verfasst von Wulan Zhao und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China. Hauptthemen laut MEDLINE: Hearing Loss, Noise-Induced, Noise, Occupational, Occupational Diseases, Occupational Exposure. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIDCD NIH HHS, Innovations Guidance Special Program for New-type Research and Development Institutions in Jiaxing, China, National Institute on Deafness and Other Communication Disorders.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Young adults with normal conventional audiograms may nonetheless show early noise-related auditory differences that routine surveillance misses. We evaluated a clinically feasible test battery using 280 occupationally noise-exposed workers and 100 age-matched low-noise controls (20-40 years; ≤20 dB HL at 0.5-8 kHz). Measures included conventional and extended high-frequency (EHF; 9-16 kHz) audiometry, distortion-product otoacoustic emissions (DPOAEs; 0.5-10 kHz), ipsilateral acoustic reflex thresholds (ARTs; 0.5, 1, and 2 kHz; 226-Hz probe tone), click-evoked auditory brainstem responses (ABR; wave I, wave V, and V/I ratio at 50 and 90 dBnHL), and Mandarin Bamford-Kowal-Bench speech-in-noise testing (SiN). Noise-exposed participants showed elevated ARTs at all elicitor frequencies, with the largest elevation at 2 kHz, as well as poorer EHF thresholds and lower DPOAE levels. In contrast, click-evoked ABR metrics did not differ between groups. After controlling for conventional-frequency pure-tone average (PTA 4 ; 0.5, 1, 2, and 4 kHz) and extended high-frequency pure-tone average (PTA EHF ; 9–16 kHz), lower DPOAE amplitudes were associated with higher ARTs. ARTs were not significantly associated with SiN performance, quantified as the signal-to-noise ratio (SNR) required for 50% correct recognition (SNR-50), cumulative noise exposure, or ABR measures. The noise-exposed group showed higher SNR-50 values, indicating poorer speech-in-noise performance. Within the noise-exposed group, SNR-50 was associated with PTA 4 and cumulative noise exposure, whereas its association with PTA EHF was weaker and did not remain significant after correction for multiple comparisons. Together, these findings suggest that cochlear-status measures, conventional ARTs, and functional SiN performance provide complementary information beyond the conventional audiogram in occupational hearing surveillance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hearing Loss, Noise-InducedNoise, OccupationalOccupational DiseasesOccupational ExposureOccupational HealthHumansAdultEvoked Potentials, Auditory, Brain StemMaleYoung AdultOtoacoustic Emissions, SpontaneousAuditory ThresholdFemaleAcoustic StimulationAudiometry, Pure-ToneReflex, AcousticAuditory AcuityCase-Control StudiesAudiometry, SpeechHearing Loss, HiddenPredictive Value of Tests

Stichwörter der Autor:innen

acoustic reflex thresholdauditory brainstem responsedistortion product otoacoustic emissionsextended high-frequency audiometryoccupational noise exposurespeech-in-noise

Autor:innen und Institutionen

  • School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China.
  • School of Rehabilitation Sciences, Université Laval, Québec City, QC, Canada.
  • Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire en Santé et en Services Sociaux de La Capitale-Nationale, Québec City, QC, Canada.
  • National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention, Beijing, China.
  • Department of Otolaryngology, The First Affiliated Hospital of Zhejiang University, Hangzhou, China.
  • Research Center for Occupational Health, Yangtze Delta Region Institute of Tsinghua University, Jiaxing, Zhejiang, China.

ORCID-Profile: Alexis Pinsonnault-Skvarenina, Wei Qiu

Förderung

  • NIDCD NIH HHS
  • Innovations Guidance Special Program for New-type Research and Development Institutions in Jiaxing, China
  • National Institute on Deafness and Other Communication Disorders

Zitieren

APA

Zhao, W., Pinsonnault-Skvarenina, A., Zhang, M., Zhang, Z., Mao, H., Bai, S., Zou, H., Guo, D., Yu, C., Fuente, A., & Qiu, W. (2026). Auditory Differences in Occupationally Noise-Exposed Workers With Normal Conventional Audiograms: A Multi-Measure Surveillance Approach. Trends in Hearing, 30. https://doi.org/10.1177/23312165261477842

Vancouver

Zhao W, Pinsonnault-Skvarenina A, Zhang M, Zhang Z, Mao H, Bai S, et al. Auditory Differences in Occupationally Noise-Exposed Workers With Normal Conventional Audiograms: A Multi-Measure Surveillance Approach. Trends in Hearing. 2026;30. doi:10.1177/23312165261477842

BibTeX
@article{Zhao2026,
  author = {Zhao, Wulan and Pinsonnault-Skvarenina, Alexis and Zhang, Meibian and Zhang, Zhili and Mao, Hangze and Bai, Shixing and Zou, Hua and Guo, Dan and Yu, Changyan and Fuente, Adrian and Qiu, Wei},
  title = {Auditory Differences in Occupationally Noise-Exposed Workers With Normal Conventional Audiograms: A Multi-Measure Surveillance Approach},
  journal = {Trends in Hearing},
  year = {2026},
  volume = {30},
  doi = {10.1177/23312165261477842}
}
Kostenlos starten →