Sex and Beam Direction Influence the Superficial Medial Collateral Ligament Radiographic Footprint: Implications for the Femoral Reconstruction Tunnel
Orthopaedic Journal of Sports Medicine · 2026-11 · 14 (11)
DOI: 10.1177/23259671261494776 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 06.11.2026. Verfasst von Mark Callanan und 6 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: arthrex, state of florida.
Abstract (Originalsprache)
Background
Prior studies have described radiographic landmarks for medial knee procedures as single points; however, the radiographic area of the superficial medial collateral ligament (sMCL) femoral origin, sex-specific differences, and the influence of x-ray beam direction have not been well studied.
Purpose
To define the entire radiographic area of the sMCL femoral origin, investigate sex-specific differences of the origin, and assess the effects of 2 different C-arm orientations on measurements. Study Design: Controlled laboratory study.
Methods
The femoral origin of the sMCL was dissected in 24 cadaveric knees (12 male, 12 female), and 2-mm radiopaque ball bearings were placed at the center and the most anterior, posterior, proximal, and distal points of the footprint. Lateral radiographs of each knee were obtained with a standard C-arm from 2 positions: with the x-ray emitter on the medial side of the knee (mediolateral) and on the lateral side of the knee (lateromedial [LM]). Landmark distances from 2 reference lines and total footprint area were measured using a Digital Imaging and Communications in Medicine viewer.
Results
Mean footprint area did not differ significantly between males and females (145.9 vs 140.4 mm 2 ; P = .70); however, the effect of beam orientation on footprint area differed significantly by sex ( P = .03). The female sMCL footprint was positioned approximately 4 mm more posterior ( P = .02) and 4 mm more proximal ( P = .01) than the male footprint. Beam direction also independently influenced landmark measurements ( P < .001), with LM imaging yielding more distal and posterior measurements from the reference lines and tighter grouping of anteroposterior measurements.
Conclusion
The radiographic position of the sMCL femoral footprint differed by sex, with a consistent proximal and posterior shift in female specimens. Positioning the x-ray emitter on the lateral side of the knee produced tighter grouping of anteroposterior landmark measurements. Both patient sex and beam direction should be considered when using intraoperative fluoroscopy. Clinical Relevance: Sex- and beam direction–specific radiographic reference values may help guide sMCL femoral tunnel placement during less invasive, fluoroscopically guided MCL reconstruction.
Förderung
- arthrex
- state of florida
Zitieren
APA
Callanan, M., Stallings, L., Blackwell, M., Truett, J., Cohen, A., Kulkarni, M., & Anz, A. W. (2026). Sex and Beam Direction Influence the Superficial Medial Collateral Ligament Radiographic Footprint: Implications for the Femoral Reconstruction Tunnel. Orthopaedic Journal of Sports Medicine, 14(11). https://doi.org/10.1177/23259671261494776
Vancouver
Callanan M, Stallings L, Blackwell M, Truett J, Cohen A, Kulkarni M, et al. Sex and Beam Direction Influence the Superficial Medial Collateral Ligament Radiographic Footprint: Implications for the Femoral Reconstruction Tunnel. Orthopaedic Journal of Sports Medicine. 2026;14(11). doi:10.1177/23259671261494776
BibTeX
@article{Callanan2026,
author = {Callanan, Mark and Stallings, Landon and Blackwell, Madison and Truett, Jessi and Cohen, Achraf and Kulkarni, Mangesh and Anz, Adam W.},
title = {Sex and Beam Direction Influence the Superficial Medial Collateral Ligament Radiographic Footprint: Implications for the Femoral Reconstruction Tunnel},
journal = {Orthopaedic Journal of Sports Medicine},
year = {2026},
volume = {14},
number = {11},
doi = {10.1177/23259671261494776}
}
EUVIMED