Automated Posterior Tibial Slope Measurement Using Lateral Knee Radiographs: A Novel Landmark-Based Approach Using Deep Learning
Orthopaedic Journal of Sports Medicine · 2025-04 · 13 (4)
DOI: 10.1177/23259671251331067 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 22.04.2025. Verfasst von ByeongYeong Ryu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
A single universally accepted protocol does not exist for measuring the posterior tibial slope (PTS), limiting the application of cutoff values for surgical decision-making and risk stratification. Purpose/Hypothesis: This purpose of this study was to validate an online computer vision model using anatomic landmarks for PTS measurement on uncalibrated lateral knee radiographs. It was hypothesized that this model would achieve similar accuracy to manual measurement. Study Design: Cohort study; Level of evidence, 2.
Methods
A total of 10,007 lateral knee radiographs collected between January 2009 and December 2019 were utilized. The data set comprised 9277 (93%) training, 500 (5%) validation, and 230 (2%) test radiographs. After defining “A” as the distance from the tibial joint line to the proximal aspect of the tibial tuberosity, 2 landmark-based methods for determining the tibial shaft axis were developed based on lines connecting the tibia midpoints at distances: (1) 2A and 3A (short method) and (2) 2A and 4A (long method). The PTS was then calculated using each tibial shaft axis. Model performance was evaluated against orthopaedic specialists’ measurements using inter- and intraobserver intraclass correlation coefficients (ICCs). Model performance on shortened images, subcategorized into normal, osteoarthritic, and implant-embedded knees, was also assessed, along with time efficiency comparisons.
Results
The overall interobservers ICCs were 0.91 for the short method and 0.92 for the long method against manual measurement. The ICCs for normal, osteoarthritic, and implant-embedded radiographs were 0.84, 0.90, and 0.97 for the short method and 0.88, 0.91, and 0.97 for the long method, respectively. The intraobserver ICC for the computer vision model was a perfect 1.00, while manual measurements showed ICCs of 0.89 for the short method and 0.95 for the long method. The mean model measurement time was 2.5 ± 0.7 seconds, compared with 26.1 ± 1.9 seconds for the manual measurement ( P < .001).
Conclusion
A novel, time-efficient, deep learning model for measuring PTS demonstrated excellent accuracy and consistency across various lateral knee radiographs. If externally validated, this model may enable a pathway for direct clinical translation of research findings by providing a standardized measurement tool.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
- CONNECTEVE Co, Ltd, Seoul, Republic of Korea.
- Innovative Medical Technology Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Orthopedic Surgery, University of Minnesota, Minneapolis, Minnesota, USA.
- Department of Orthopedic Surgery, CentraCare, Saint Cloud, Minnesota, USA.
- Oslo Sports Trauma Research Center, Norwegian School of Sports Science, Oslo, Norway.
Zitieren
APA
Ryu, B., Nam, J. W., Ro, D. H., Martin, R. K., Inderhaug, E., Persson, A., Haland, S., & Kim, S. E. (2025). Automated Posterior Tibial Slope Measurement Using Lateral Knee Radiographs: A Novel Landmark-Based Approach Using Deep Learning. Orthopaedic Journal of Sports Medicine, 13(4). https://doi.org/10.1177/23259671251331067
Vancouver
Ryu B, Nam JW, Ro DH, Martin RK, Inderhaug E, Persson A, et al. Automated Posterior Tibial Slope Measurement Using Lateral Knee Radiographs: A Novel Landmark-Based Approach Using Deep Learning. Orthopaedic Journal of Sports Medicine. 2025;13(4). doi:10.1177/23259671251331067
BibTeX
@article{Ryu2025,
author = {Ryu, ByeongYeong and Nam, Jun Woo and Ro, Du Hyun and Martin, R Kyle and Inderhaug, Eivind and Persson, Andreas and Haland, Sanna and Kim, Sung Eun},
title = {Automated Posterior Tibial Slope Measurement Using Lateral Knee Radiographs: A Novel Landmark-Based Approach Using Deep Learning},
journal = {Orthopaedic Journal of Sports Medicine},
year = {2025},
volume = {13},
number = {4},
doi = {10.1177/23259671251331067}
}