EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Reliability of MRI Interpretation of Discoid Lateral Meniscus: A Multicenter Study

Emily L Niu, Matthew D Milewski, Craig J Finlayson, Zachary S Stinson, Elaine Joughin, Jeffrey J Nepple, Gregory A Schmale, PRiSM Meniscus Research Interest Group, Jennifer J Beck

Orthopaedic Journal of Sports Medicine · 01.05.2023 · 11 (5)

DOI: 10.1177/23259671231174475 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 30.05.2023. Verfasst von Emily L Niu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Children's National Hospital, Washington, DC, USA. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Discoid lateral meniscus (DLM) has a varied and complex morphology that can be challenging to assess and treat. Preoperative magnetic resonance imaging (MRI) is frequently used for diagnosis and surgical planning; however, it is not known whether surgeons are reliable and accurate in their interpretation of MRI findings when defining the pathomorphology of DLM. Hypothesis: Surgeons experienced in treating DLM are able to reliably interpret DLM pathology using MRI. Study Design: Cohort study (diagnosis); Level of evidence, 3.

Methods

Knee MRI scans from 44 patients (45 knees) were selected from a pool of surgically treated patients with DLM. Five reviewers (fellowship-trained pediatric sports medicine surgeons) performed independent review of each MRI scan using the PRiSM Discoid Meniscus Classification. Inter- and intraobserver reliability of the rating factors—primary (width, height, presence of peripheral instability or tear) and secondary (location of instability or tear, tear type)—was assessed using the Fleiss κ coefficient, designed for multiple readers with nominal variables (fair reliability, 0.21-0.40; moderate, 0.41-0.60; substantial, 0.61-0.80; excellent, 0.81-1.00). Reliability is reported as κ (95% CI).

Results

Interobserver reliability in assessing most primary and secondary characteristics ranged from substantial (meniscal width) to moderate (peripheral instability, anterior instability, posterior instability, and posterior tear). Intraobserver reliability for most characteristics ranged from substantial (peripheral instability, presence of tear, anterior instability, posterior instability, and posterior tear) to moderate (meniscal width, anterior tear, and tear type). Notable exceptions were presence of tear, anterior tear, and tear type—all with fair interobserver reliability. Height had poor interobserver reliability and fair intraobserver reliability.

Conclusion

Orthopaedic surgeons reliably interpret MRI scans using the PRiSM Discoid Meniscus Classification for the majority of DLM characteristics but vary in their assessment of height and presence and type of tear. MRI evaluation may be helpful to diagnose discoid by width and identify the presence of instability: 2 major factors in the decision to proceed with surgery. Arthroscopic evaluation should be used in conjunction with MRI findings for complete DLM diagnosis.

Schlagwörter

Stichwörter der Autor:innen

classificationdiscoid meniscusmagnetic resonance imaging

Autor:innen und Institutionen

  • Children's National Hospital, Washington, DC, USA.
  • Boston Children's Hospital, Boston, Massachusetts, USA.
  • Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois, USA.
  • Nemours Children's Hospital, Orlando, Florida, USA.
  • Alberta Children's Hospital, Calgary, Alberta, Canada.
  • Washington University School of Medicine, St Louis, Missouri, USA.

Zitieren

APA

Niu, E. L., Milewski, M. D., Finlayson, C. J., Stinson, Z. S., Joughin, E., Nepple, J. J., Schmale, G. A., PRiSM Meniscus Research Interest Group, & Beck, J. J. (2023). Reliability of MRI Interpretation of Discoid Lateral Meniscus: A Multicenter Study. Orthopaedic Journal of Sports Medicine, 11(5). https://doi.org/10.1177/23259671231174475

Vancouver

Niu EL, Milewski MD, Finlayson CJ, Stinson ZS, Joughin E, Nepple JJ, et al. Reliability of MRI Interpretation of Discoid Lateral Meniscus: A Multicenter Study. Orthopaedic Journal of Sports Medicine. 2023;11(5). doi:10.1177/23259671231174475

BibTeX
@article{Niu2023,
  author = {Niu, Emily L and Milewski, Matthew D and Finlayson, Craig J and Stinson, Zachary S and Joughin, Elaine and Nepple, Jeffrey J and Schmale, Gregory A and PRiSM Meniscus Research Interest Group, PRiSM Meniscus Research Interest Group and Beck, Jennifer J},
  title = {Reliability of MRI Interpretation of Discoid Lateral Meniscus: A Multicenter Study},
  journal = {Orthopaedic Journal of Sports Medicine},
  year = {2023},
  volume = {11},
  number = {5},
  doi = {10.1177/23259671231174475}
}
Kostenlos starten →