EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Preliminary in vitro evaluation of biological responses associated with an Elumbotti-derived coating on titanium cortical screws

Geetha Balasubramani iD, Premkumar J, Paul Pradeep J

Journal of Applied Biomaterials & Functional Materials · 2026-10 · 24

DOI: 10.1177/22808000261503018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Biomaterials & Functional Materials, online erschienen am 02.11.2026. Verfasst von Geetha Balasubramani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Bio and Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India. Hauptthemen laut MEDLINE: Titanium, Coated Materials, Biocompatible, Bone Screws, Osteoblasts. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biological response to coating-derived components is an important consideration in the preliminary development of functionalized titanium implants. In the present study, an Elumbotti ( Ormocarpum cochinchinense )-derived composite coating was applied to titanium cortical screws (12 mm), and its preliminary in vitro biological response was investigated using a cell-free protein-denaturation assay and MG-63 osteoblast-like cells. Uncoated titanium (T1) and Elumbotti-coated titanium cortical screw samples (ST1) were included in the experimental evaluation. Bovine serum albumin (BSA) protein-denaturation inhibition was assessed as a preliminary cell-free measure of protein-stabilizing activity, with diclofenac sodium used as the reference standard. MG-63 cellular responses were evaluated using MTT viability, scratch-wound closure, and acridine orange/ethidium bromide (AO/EtBr) fluorescence staining assays. The MTT assay evaluated concentration-dependent responses to the ST1 test preparation, whereas the scratch-wound and AO/EtBr assays evaluated cellular responses following exposure to conditioned medium obtained from ST1-coated titanium cortical screws. ST1 demonstrated greater BSA protein-denaturation inhibitory activity than T1, with calculated IC 50 values of 63.032 and 118.379 µg/mL, respectively. In the MTT assay, MG-63 viability showed a concentration-dependent response to the ST1 test preparation, remaining above 70% at concentrations up to 32 µg/mL and decreasing below 70% at concentrations of 64 µg/mL and above. Scratch-wound closure following exposure to ST1-conditioned medium increased from 67.07% at 24 h to 83.45% at 48 h, compared with 27.24% and 34.50%, respectively, in untreated control cells. AO/EtBr staining demonstrated time-dependent changes in cell viability and membrane integrity following prolonged exposure to ST1-conditioned medium. Overall, the findings provide preliminary evidence of concentration- and time-dependent biological responses associated with the Elumbotti-derived coating system and its soluble components. However, the present assays do not establish direct cell–coating interactions, cellular anti-inflammatory activity, osteogenic differentiation, osseointegration, or improved orthopedic implant performance. Further batch-specific physicochemical characterization, direct cell–surface studies, coating stability and release analyses, osteogenic and inflammatory-marker evaluation, and in vivo investigation are required to establish the biological and functional relevance of the coating for orthopedic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumCoated Materials, BiocompatibleBone ScrewsOsteoblastsHumansAnimalsCell LineCell SurvivalSerum Albumin, BovineCattle

Stichwörter der Autor:innen

Elumbotti-derived coatingMG-63 cellsOrmocarpum cochinchinenseconditioned mediumcytotoxicityprotein-denaturation inhibitionscratch-wound closuretitanium cortical screw

Substanzen

TitaniumCoated Materials, BiocompatibleSerum Albumin, Bovine

Autor:innen und Institutionen

  • Department of Biomedical Engineering, School of Bio and Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India.
  • MedCuore Medical Solutions Private Limited, Chennai, India.

ORCID-Profile: Geetha Balasubramani

Zitieren

APA

Balasubramani, G., J, P., & J, P. P. (2026). Preliminary in vitro evaluation of biological responses associated with an Elumbotti-derived coating on titanium cortical screws. Journal of Applied Biomaterials & Functional Materials, 24. https://doi.org/10.1177/22808000261503018

Vancouver

Balasubramani G, J P, J PP. Preliminary in vitro evaluation of biological responses associated with an Elumbotti-derived coating on titanium cortical screws. Journal of Applied Biomaterials & Functional Materials. 2026;24. doi:10.1177/22808000261503018

BibTeX
@article{Balasubramani2026,
  author = {Balasubramani, Geetha and J, Premkumar and J, Paul Pradeep},
  title = {Preliminary in vitro evaluation of biological responses associated with an Elumbotti-derived coating on titanium cortical screws},
  journal = {Journal of Applied Biomaterials & Functional Materials},
  year = {2026},
  volume = {24},
  doi = {10.1177/22808000261503018}
}
Kostenlos starten →