Surgical accuracy of implant positioning in robotic-assisted versus conventional total hip arthroplasty – Experience of a Joint Replacement Centre in Hong Kong
Journal of Orthopaedics, Trauma and Rehabilitation · 27.05.2026
DOI: 10.1177/22104917261451433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedics, Trauma and Rehabilitation, online erschienen am 27.05.2026. Verfasst von Chun-Lai Wong und 5 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Total hip arthroplasty (THA) is a common orthopaedic procedure that significantly alleviates pain and enhances the quality of life for patients with hip osteoarthritis. Precise implant placement is critical for successful outcomes. Robotic-assisted THA has been developed to improve surgical accuracy and predictability, offering three-dimensional computed tomography-based planning and haptic guidance during key steps of surgery such as reaming and cup impaction. This study aims to compare (i) the accuracy of implant positioning between robotic-assisted and conventional THA, and (ii) other intra-operative and post-operative outcomes, including blood loss, operative time, length of stay, and associated complications. Materials and Methods : In total, 97 THA cases performed between November 2017 and October 2023, with a minimum follow-up of one year, were retrospectively analyzed. Fifty patients underwent robotic-assisted THA, while 47 received conventional THA. Demographic data, radiographic outcomes, surgical time, blood loss, length of stay, and surgical complications were evaluated. Intra- and Inter-observer reliability of radiographic measurements was confirmed.
Results
Robotic-assisted THA demonstrated significantly greater accuracy and consistency in achieving targeted acetabular inclination and anteversion (p < 0.001). More cases in this group fell within the Lewinnek (
Zitieren
APA
Wong, C., Chau, W., Hui, K. R., To, C., Hui, S. K., & Wong, M. (2026). Surgical accuracy of implant positioning in robotic-assisted versus conventional total hip arthroplasty – Experience of a Joint Replacement Centre in Hong Kong. Journal of Orthopaedics, Trauma and Rehabilitation. https://doi.org/10.1177/22104917261451433
Vancouver
Wong C, Chau W, Hui KR, To C, Hui SK, Wong M. Surgical accuracy of implant positioning in robotic-assisted versus conventional total hip arthroplasty – Experience of a Joint Replacement Centre in Hong Kong. Journal of Orthopaedics, Trauma and Rehabilitation. 2026. doi:10.1177/22104917261451433
BibTeX
@article{Wong2026,
author = {Wong, Chun-Lai and Chau, Wai-Wang and Hui, Kar-Ching Raymond and To, Chak-Yam and Hui, Siu-Hung Kenneth and Wong, Man-Kwan},
title = {Surgical accuracy of implant positioning in robotic-assisted versus conventional total hip arthroplasty – Experience of a Joint Replacement Centre in Hong Kong},
journal = {Journal of Orthopaedics, Trauma and Rehabilitation},
year = {2026},
doi = {10.1177/22104917261451433}
}
EUVIMED