EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Augmented Reality-Assisted Spine Surgery: An Early Experience Demonstrating Safety and Accuracy with 218 Screws

Fenil R Bhatt iD, Lindsay D Orosz iD, Anant Tewari, David Boyd, Rita Roy, Christopher R Good, Thomas C Schuler, Colin M Haines, Ehsan Jazini

Global Spine Journal · 2023-09 · 13 (7) · 2047-2052

DOI: 10.1177/21925682211069321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Global Spine Journal, online erschienen am 10.01.2022. Verfasst von Fenil R Bhatt und 8 weiteren Autor:innen. Beteiligte Einrichtung: Virginia Spine Institute, Reston, VA, USA. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Study Design Prospective cohort study.

Objectives

In spine surgery, accurate screw guidance is critical to achieving satisfactory fixation. Augmented reality (AR) is a novel technology to assist in screw placement and has shown promising results in early studies. This study aims to provide our early experience evaluating safety and efficacy with an Food and Drug Administration-approved head-mounted (head-mounted device augmented reality (HMD-AR)) device.

Methods

Consecutive adult patients undergoing AR-assisted thoracolumbar fusion between October 2020 and August 2021 with 2 -week follow-up were included. Preoperative, intraoperative, and postoperative data were collected to include demographics, complications, revision surgeries, and AR performance. Intraoperative 3D imaging was used to assess screw accuracy using the Gertzbein-Robbins (G-R) grading scale.

Results

Thirty-two patients (40.6% male) were included with a total of 222 screws executed using HMD-AR. Intraoperatively, 4 (1.8%) were deemed misplaced and revised using AR or freehand. The remaining 218 (98.2%) screws were placed accurately. There were no intraoperative adverse events or complications, and AR was not abandoned in any case. Of the 208 AR-placed screws with 3D imaging confirmation, 97.1% were considered clinically accurate (91.8% Grade A, 5.3% Grade B). There were no early postoperative surgical complications or revision surgeries during the 2 -week follow-up.

Conclusions

This early experience study reports an overall G-R accuracy of 97.1% across 218 AR-guided screws with no intra or early postoperative complications. This shows that HMD-AR-assisted spine surgery is a safe and accurate tool for pedicle, cortical, and pelvic fixation. Larger studies are needed to continue to support this compelling evolution in spine surgery.

Schlagwörter

Stichwörter der Autor:innen

augmented realitycomplicationscortical screwfixationpedicle screwrevisionsthoracolumbar fusion

Autor:innen und Institutionen

  • Virginia Spine Institute, Reston, VA, USA.
  • National Spine Health Foundation, Reston, VA, USA.
  • Reston Radiology Consultants, Reston, VA, USA.

ORCID-Profile: Fenil R Bhatt, Lindsay D Orosz

Zitieren

APA

Bhatt, F. R., Orosz, L. D., Tewari, A., Boyd, D., Roy, R., Good, C. R., Schuler, T. C., Haines, C. M., & Jazini, E. (2023). Augmented Reality-Assisted Spine Surgery: An Early Experience Demonstrating Safety and Accuracy with 218 Screws. Global Spine Journal, 13(7), 2047-2052. https://doi.org/10.1177/21925682211069321

Vancouver

Bhatt FR, Orosz LD, Tewari A, Boyd D, Roy R, Good CR, et al. Augmented Reality-Assisted Spine Surgery: An Early Experience Demonstrating Safety and Accuracy with 218 Screws. Global Spine Journal. 2023;13(7):2047-2052. doi:10.1177/21925682211069321

BibTeX
@article{Bhatt2023,
  author = {Bhatt, Fenil R and Orosz, Lindsay D and Tewari, Anant and Boyd, David and Roy, Rita and Good, Christopher R and Schuler, Thomas C and Haines, Colin M and Jazini, Ehsan},
  title = {Augmented Reality-Assisted Spine Surgery: An Early Experience Demonstrating Safety and Accuracy with 218 Screws},
  journal = {Global Spine Journal},
  year = {2023},
  volume = {13},
  number = {7},
  pages = {2047--2052},
  doi = {10.1177/21925682211069321}
}
Kostenlos starten →