Assessment of Anesthesia Providers’ Radiation Safety Practices Using Operating Room Black Box Data
Workplace Health & Safety · 28.10.2026
DOI: 10.1177/21650799261493078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Workplace Health & Safety, online erschienen am 28.10.2026. Verfasst von Soo Jung Ha und 4 weiteren Autor:innen. Beteiligte Einrichtung: Duke University School of Nursing. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Background
Advancements in medical imaging led to increased usage of ionizing radiation in operating rooms. However, despite radiation safety guidelines, studies report suboptimal compliance with only 50% of healthcare providers demonstrating adequate knowledge of radiation safety practices. The purpose of this project was to evaluate anesthesia providers’ compliance with radiation safety practices and identify recommendations to improve radiation safety practices.
Methods
The project was conducted at an academic hospital in the Southeastern United States. The Operating Room Black Box ® (ORBB; Surgical Safety Technology Inc., New York) was used to retrospectively review de-identified video recordings and assess anesthesia providers’ compliance with radiation safety practices (adequate shielding, maximum distance from radiation, and appropriate lead storage). A survey was also distributed to assess self-reported practices and barriers related to radiation safety.
Findings
Thirty-four anesthesia providers were observed across 82 video clips. Findings revealed 53% ( n = 18) appropriately wore lead aprons and thyroid shields. However, 29% ( n = 10) did not wear lead aprons and 41% ( n = 14) did not wear thyroid shields. Only 38% ( n = 13) of providers demonstrated observable efforts to maximize distance from radiation source, and 53% ( n = 10) appropriately stored lead aprons. Barriers were driven by environmental and workflow challenges, such as limited storage space and the need to remain near the radiation source for patient care.
Conclusion
Recommendations to mitigate barriers include increasing radiation personal protective equipment availability, standardizing communication prior to radiation use, and providing periodic refresher training.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Duke University School of Nursing.
- Duke University Hospital.
ORCID-Profile: Hideyo Tsumura, Staci Reynolds
Zitieren
APA
Ha, S. J., Stalzer, A., Tsumura, H., Dodd, B., & Reynolds, S. (2026). Assessment of Anesthesia Providers’ Radiation Safety Practices Using Operating Room Black Box Data. Workplace Health & Safety. https://doi.org/10.1177/21650799261493078
Vancouver
Ha SJ, Stalzer A, Tsumura H, Dodd B, Reynolds S. Assessment of Anesthesia Providers’ Radiation Safety Practices Using Operating Room Black Box Data. Workplace Health & Safety. 2026. doi:10.1177/21650799261493078
BibTeX
@article{Ha2026,
author = {Ha, Soo Jung and Stalzer, Alyson and Tsumura, Hideyo and Dodd, Bailey and Reynolds, Staci},
title = {Assessment of Anesthesia Providers’ Radiation Safety Practices Using Operating Room Black Box Data},
journal = {Workplace Health & Safety},
year = {2026},
doi = {10.1177/21650799261493078}
}
EUVIMED