Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
Acta Radiologica Open · 2023-05 · 12 (5) · 205846012311774
DOI: 10.1177/20584601231177404 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Radiologica Open, online erschienen am 20.05.2023. Verfasst von José Gerardo Fleiderman Valenzuela und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedics and Traumatology Department, Clínica Universidad de Los Andes, Las Condes, Chile. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap.
Purpose
To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise. Material and Methods Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements.
Results
Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85–0.99]; TCM: PCC 0.90 [0.81–0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s.
Conclusion
Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopedics and Traumatology Department, Clínica Universidad de Los Andes, Las Condes, Chile.
- Orthopedics and Traumatology Department, Hospital Del Trabajador, Providencia, Chile.
- Medical Imaging Department, Clínica Universidad de Los Andes, Las Condes, Chile.
- Orthopedcis and Traumatology Residence Program, Universidad de Los Andes, Las Condes, Chile.
ORCID-Profile: Felipe Ignacio Arriagada Ramos
Zitieren
APA
Fleiderman Valenzuela, J. G., Cirillo Totera, J. I., Turkieltaub, D. H., Echaurren, C. V., Álvarez Lemos, F. L., & Arriagada Ramos, F. I. (2023). Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap). Acta Radiologica Open, 12(5), 205846012311774. https://doi.org/10.1177/20584601231177404
Vancouver
Fleiderman Valenzuela JG, Cirillo Totera JI, Turkieltaub DH, Echaurren CV, Álvarez Lemos FL, Arriagada Ramos FI. Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap). Acta Radiologica Open. 2023;12(5):205846012311774. doi:10.1177/20584601231177404
BibTeX
@article{FleidermanValenzuela2023,
author = {Fleiderman Valenzuela, José Gerardo and Cirillo Totera, Juan Ignacio and Turkieltaub, Diego Herreros and Echaurren, Cristóbal Varela and Álvarez Lemos, Facundo Lisandro and Arriagada Ramos, Felipe Ignacio},
title = {Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)},
journal = {Acta Radiologica Open},
year = {2023},
volume = {12},
number = {5},
pages = {205846012311774},
doi = {10.1177/20584601231177404}
}
EUVIMED