The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
Journal of Rehabilitation and Assistive Technologies Engineering · 2018-01 · 5
DOI: 10.1177/2055668318795402 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Rehabilitation and Assistive Technologies Engineering, online erschienen am 18.11.2018. Verfasst von Hiroshi Hashimoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Comprehensive Rehabilitation, Osaka Prefecture University, Habikino City, Osaka, Japan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
The alignment of a prosthesis is clinically determined based on observations by clinicians and the subjective perception of amputees during gait. However, this process has been reported to be unreliable. Socket reaction moment has been reported to be significantly impacted by alignment changes, but the impact of these alignment changes on other gait parameters is unclear. The aim of this study was to investigate the effects of coronal alignment changes of a transtibial prosthesis on socket reaction moment, spatiotemporal parameters, and perceptions of alignment during gait in amputees.
Methods
Nine individuals with transtibial amputation participated in this study. Socket reaction moment and spatiotemporal parameters (step time, step length, step width, single limb support time, cadence, and gait speed) were measured under nine coronal alignment conditions (angulation: ±3°, ±6°, translation: ±5 mm, ±10 mm, and baseline) using a three-dimensional motion capture system (Vicon) and an embedded load-cell system (Europa™). In addition, subjective perceptions of alignment were examined.
Results
Coronal alignment changes of the transtibial prostheses demonstrated significant changes in socket reaction moment; however, no significant changes were found with spatiotemporal parameters or the amputee’s perception.
Conclusion
Measurement of socket reaction moment, along with the embedded load-cell system, may be a better metric for tuning the coronal alignment of transtibial prostheses compared to spatiotemporal parameters and amputee’s perceptions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Comprehensive Rehabilitation, Osaka Prefecture University, Habikino City, Osaka, Japan.
- Pacific Supply Co. Ltd, Daito City, Osaka, Japan.
- Department of Prosthetics and Orthotics, Faculty of Health Science, Hokkaido University of Science, Sapporo, Hokkaido, Japan.
- Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY, USA.
Zitieren
APA
Hashimoto, H., Kobayashi, T., Gao, F., Kataoka, M., & Okuda, K. (2018). The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation. Journal of Rehabilitation and Assistive Technologies Engineering, 5. https://doi.org/10.1177/2055668318795402
Vancouver
Hashimoto H, Kobayashi T, Gao F, Kataoka M, Okuda K. The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation. Journal of Rehabilitation and Assistive Technologies Engineering. 2018;5. doi:10.1177/2055668318795402
BibTeX
@article{Hashimoto2018,
author = {Hashimoto, Hiroshi and Kobayashi, Toshiki and Gao, Fan and Kataoka, Masataka and Okuda, Kuniharu},
title = {The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation},
journal = {Journal of Rehabilitation and Assistive Technologies Engineering},
year = {2018},
volume = {5},
doi = {10.1177/2055668318795402}
}
EUVIMED