EUVIMEDEUVIMED entdecken
Open Access

The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation

Hiroshi Hashimoto, Toshiki Kobayashi, Fan Gao, Masataka Kataoka, Kuniharu Okuda

Journal of Rehabilitation and Assistive Technologies Engineering · 2018-01 · 5

DOI: 10.1177/2055668318795402 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Rehabilitation and Assistive Technologies Engineering, online erschienen am 18.11.2018. Verfasst von Hiroshi Hashimoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Comprehensive Rehabilitation, Osaka Prefecture University, Habikino City, Osaka, Japan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The alignment of a prosthesis is clinically determined based on observations by clinicians and the subjective perception of amputees during gait. However, this process has been reported to be unreliable. Socket reaction moment has been reported to be significantly impacted by alignment changes, but the impact of these alignment changes on other gait parameters is unclear. The aim of this study was to investigate the effects of coronal alignment changes of a transtibial prosthesis on socket reaction moment, spatiotemporal parameters, and perceptions of alignment during gait in amputees.

Methods

Nine individuals with transtibial amputation participated in this study. Socket reaction moment and spatiotemporal parameters (step time, step length, step width, single limb support time, cadence, and gait speed) were measured under nine coronal alignment conditions (angulation: ±3°, ±6°, translation: ±5 mm, ±10 mm, and baseline) using a three-dimensional motion capture system (Vicon) and an embedded load-cell system (Europa™). In addition, subjective perceptions of alignment were examined.

Results

Coronal alignment changes of the transtibial prostheses demonstrated significant changes in socket reaction moment; however, no significant changes were found with spatiotemporal parameters or the amputee’s perception.

Conclusion

Measurement of socket reaction moment, along with the embedded load-cell system, may be a better metric for tuning the coronal alignment of transtibial prostheses compared to spatiotemporal parameters and amputee’s perceptions.

Schlagwörter

Stichwörter der Autor:innen

Amputeeload cellprosthesisprosthetistwalk

Autor:innen und Institutionen

  • Graduate School of Comprehensive Rehabilitation, Osaka Prefecture University, Habikino City, Osaka, Japan.
  • Pacific Supply Co. Ltd, Daito City, Osaka, Japan.
  • Department of Prosthetics and Orthotics, Faculty of Health Science, Hokkaido University of Science, Sapporo, Hokkaido, Japan.
  • Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY, USA.

Zitieren

APA

Hashimoto, H., Kobayashi, T., Gao, F., Kataoka, M., & Okuda, K. (2018). The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation. Journal of Rehabilitation and Assistive Technologies Engineering, 5. https://doi.org/10.1177/2055668318795402

Vancouver

Hashimoto H, Kobayashi T, Gao F, Kataoka M, Okuda K. The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation. Journal of Rehabilitation and Assistive Technologies Engineering. 2018;5. doi:10.1177/2055668318795402

BibTeX
@article{Hashimoto2018,
  author = {Hashimoto, Hiroshi and Kobayashi, Toshiki and Gao, Fan and Kataoka, Masataka and Okuda, Kuniharu},
  title = {The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation},
  journal = {Journal of Rehabilitation and Assistive Technologies Engineering},
  year = {2018},
  volume = {5},
  doi = {10.1177/2055668318795402}
}
Kostenlos starten →