A unified VQ-VAE framework for few-shot retinal vessel segmentation and multidisease classification
DIGITAL HEALTH · 2026-02 · 12
DOI: 10.1177/20552076261433086 ↗Kurz gefasst
Fachartikel in der Zeitschrift DIGITAL HEALTH, online erschienen am 18.03.2026. Verfasst von Haojun Yu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Medicine, Chongqing Medical University-University of Leicester Joint Institute, Chongqing Medical University, Chongqing, China. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
To address the reliance of task-specific deep learning models on large annotated datasets, this study investigates a Vector Quantized Variational Autoencoder (VQ-VAE) based few-shot learning framework for retinal vessel segmentation and disease classification.
Methods
A compact VQ-VAE was pretrained on unlabeled fundus photographs to learn transferable discrete representations. The pretrained encoder was used to initialize multiple downstream models, including segmentation networks (U-Net, SegNet, ERFNet) and three additional architectures (FR-UNet, Swin-Res-Net, RV-GAN), as well as classification networks (VGG-16, ResNet-50, EfficientNet-B0). Retinal vessel segmentation was evaluated on three public datasets (DRIVE, STructured Analysis of the Retina [STARE], and CHASE), while disease classification was assessed on the Retina and Ocular Disease Intelligent Recognition (ODIR) datasets. Segmentation performance was evaluated using Dice coefficient, Recall, Accuracy, Intersection over Union (IoU), mean IoU, and Average Offset Distance. Classification performance was assessed using accuracy, precision, recall, F1-score, and area under the receiver operating characteristic curve (AUC), with additional validation on the heterogeneous ODIR dataset.
Results
The VQ-VAE pretraining consistently improved performance under small-sample conditions. On the DRIVE dataset, Dice scores increased by approximately 2 percentage points across all segmentation backbones, with U-Net improving from 0.780 to 0.796 and SegNet from 0.670 to 0.692. Consistent performance improvements were also observed on the STARE and CHASE datasets. For disease classification on the Retina dataset, accuracy increased from 20% to 60% using only 70 labeled images. On the ODIR dataset, mean AUC improved across architectures, from 0.677 to 0.724 for VGG-16, 0.684 to 0.745 for ResNet-50, and 0.664 to 0.726 for EfficientNet-B0, indicating enhanced robustness across diverse disease categories and imaging conditions.
Conclusion
The proposed pretraining framework effectively reduces labeled data requirements while improving performance across multiple ophthalmic tasks, offering a scalable and resource-efficient solution for real-world clinical applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical Medicine, Chongqing Medical University-University of Leicester Joint Institute, Chongqing Medical University, Chongqing, China.
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, London, UK.
- Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong, Hong Kong Special Administrative Region of China.
ORCID-Profile: Xinyu Xu
Zitieren
APA
Yu, H., Tan, Z., Liu, H., & Xu, X. (2026). A unified VQ-VAE framework for few-shot retinal vessel segmentation and multidisease classification. DIGITAL HEALTH, 12. https://doi.org/10.1177/20552076261433086
Vancouver
Yu H, Tan Z, Liu H, Xu X. A unified VQ-VAE framework for few-shot retinal vessel segmentation and multidisease classification. DIGITAL HEALTH. 2026;12. doi:10.1177/20552076261433086
BibTeX
@article{Yu2026,
author = {Yu, Haojun and Tan, Zongcai and Liu, Huazhen and Xu, Xinyu},
title = {A unified VQ-VAE framework for few-shot retinal vessel segmentation and multidisease classification},
journal = {DIGITAL HEALTH},
year = {2026},
volume = {12},
doi = {10.1177/20552076261433086}
}
EUVIMED