Smartwatch-based ventilatory assessment for COPD screening: A diagnostic accuracy study
DIGITAL HEALTH · 2025-05 · 11
DOI: 10.1177/20552076251377938 ↗Kurz gefasst
Fachartikel in der Zeitschrift DIGITAL HEALTH, online erschienen am 17.09.2025. Verfasst von Yibing Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary and Critical Care Medicine, The First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: the China Key Scientific Grant.
Themen: COPD
Abstract (Originalsprache)
Background
COPD underdiagnosis persists in China due to limited spirometry access. Smart wearables enabling cough and physiological monitoring (SpO 2 , respiratory rate) offer a scalable screening solution.
Methods
Participants were randomly allocated to training and validation cohorts. All underwent cough sound recordings, smartwatch monitoring (heart rate variability, respiratory rate, oxygen saturation), and pre-/post-bronchodilator spirometry. Machine learning algorithms extracted cough sound features to predict lung function (evaluated via MAE, Pearson correlation, and Bland-Altman analysis). These predictions were combined with physiological data in a multimodal COPD screening model, with diagnostic performance assessed against physician diagnosis.
Results
The training cohort included 178 patients (112 males) with COPD or pulmonary dysfunctions, aged 54.42 ± 14.77 years, BMI 24.81 ± 3.73 kg/m², FVC 3.64 ± 1.09 L, and FEV 1 2.42 ± 0.96 L, alongside 298 healthy volunteers (151 males) aged 35.3 ± 12.35 years, BMI 22.62 ± 3.12 kg/m², FVC 3.63 ± 0.89 L, and FEV 1 3.14 ± 0.73 L. The validation cohort comprised 47 COPD patients (35 males) aged 65.53 ± 7.62 years, BMI 25.38 ± 4.38 kg/m², FVC 3.27 ± 0.59 L, and FEV 1 1.91 ± 0.50 L, and 71 healthy controls (27 males) aged 45.51 ± 12.15 years, BMI 25.79 ± 4.00 kg/m², FVC 3.35 ± 0.80 L, and FEV 1 2.72 ± 0.67 L. Using cough sounds, the model's mean absolute error for FEV 1 /FVC, FVC%, and FEV 1 % prediction was 7.4%, 10.6%, and 17.78% ( Table 3 – 5 ), respectively, compared to spirometry. Significant correlations were found between predicted and measured FVC (r = 0.798, P < 0.001), FEV 1 (r = 0.752, P < 0.001), and FEV 1 /FVC (r = 0.784, < 0.001) ( Table 6 ). Combined with physiological parameters, our model's overall accuracy, sensitivity, and specificity for differentiating between COPD and normal controls were 87.82%, 86.96%, and 87.73% ( Table 9 ).
Conclusion
Our wearable-based algorithm effectively screens for ventilatory dysfunction and COPD, showing potential for large-scale population screening to reduce medical burdens. Trial Registration Chinese Clinical Trial Registry of the International Clinical Trials Registry Platform of the World Health Organization ChiCTR2100050843; Registration Date: 2021-9-4 Clinical Trial Number: ChiCTR2100050843. https://www.chictr.org.cn/showproj.html?proj=126556
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pulmonary and Critical Care Medicine, The First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China.
- Senior Department of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, 100091, China.
- Huawei Device Co., Ltd, Shenzhen, 518129, China.
- Chinese Association of Geriatric Research, The First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China.
ORCID-Profile: Yibing Chen
Förderung
- the China Key Scientific Grant
Zitieren
APA
Chen, Y., Cao, L., Zhao, D., Meng, S., Li, D., Li, J., Cui, Y., & Xie, L. (2025). Smartwatch-based ventilatory assessment for COPD screening: A diagnostic accuracy study. DIGITAL HEALTH, 11. https://doi.org/10.1177/20552076251377938
Vancouver
Chen Y, Cao L, Zhao D, Meng S, Li D, Li J, et al. Smartwatch-based ventilatory assessment for COPD screening: A diagnostic accuracy study. DIGITAL HEALTH. 2025;11. doi:10.1177/20552076251377938
BibTeX
@article{Chen2025,
author = {Chen, Yibing and Cao, Lu and Zhao, Dahui and Meng, Song and Li, Dan and Li, Jing and Cui, Yuqi and Xie, Lixin},
title = {Smartwatch-based ventilatory assessment for COPD screening: A diagnostic accuracy study},
journal = {DIGITAL HEALTH},
year = {2025},
volume = {11},
doi = {10.1177/20552076251377938}
}
EUVIMED