Effect of abdominal circumference on spread of intrathecal heavy bupivacaine in parturient undergoing cesarean section: An observational study
Sage Open Medicine · 2026-05 · 14
DOI: 10.1177/20503121261455201 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sage Open Medicine, online erschienen am 23.05.2026. Verfasst von Prasant Silwal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiolog, Sindhuli Hospital, Sindhuli, Nepal. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Spinal anesthesia is a widely preferred anesthetic technique for cesarean section but often leads to adverse effects such as nausea, vomiting, hypotension, bradycardia, and shivering, which are primarily attributed to increased intra-abdominal pressure. Since abdominal circumference correlates with intra-abdominal pressure in parturients, the objective is to investigate how abdominal circumference influences the spread of intrathecal heavy bupivacaine following spinal anesthesia during cesarean section. Methodology A total of 78 pregnant women with singleton gestation undergoing cesarean section under spinal anesthesia were enrolled in the study. Preoperative parturient abdominal circumference was measured. Lumbar puncture was performed at the L3-L4 interspinous space using a Quincke 25-gauge spinal needle with a midline approach in the sitting position, followed by the intrathecal administration of 2 mL of 0.5% heavy bupivacaine. The cephalic spread of local anesthetic was assessed by evaluating the dermatomal level of cold-sensation loss at 1, 3, 5, 10, and 15 minutes following spinal anesthesia. Kendall’s tau correlation analysis was used to assess the relationship between parturient abdominal circumference and the sensory block level at various time intervals.
Results
No correlation was found between parturient abdominal circumference and the level of loss of cold sensation at various time intervals. The incidence rates of adverse effects were as follows: hypotension (44.4%), bradycardia (4.2%), nausea (4.2%), vomiting (2.8%), and shivering (18.1%).
Conclusion
Our study found no correlation between parturient abdominal circumference and the intrathecal spread of heavy bupivacaine following spinal anesthesia during cesarean section.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiolog, Sindhuli Hospital, Sindhuli, Nepal.
- Department of Obstetrics and Gynecology, Sindhuli Hospital, Sindhuli, Nepal.
- Operating Theatre, Department of Perioperative Services, Sindhuli Hospital, Sindhuli, Nepal.
ORCID-Profile: Prasant Silwal, Sangita Pudasaini, Elisha Thapa Magar
Zitieren
APA
Silwal, P., Pudasaini, S., & Magar, E. T. (2026). Effect of abdominal circumference on spread of intrathecal heavy bupivacaine in parturient undergoing cesarean section: An observational study. Sage Open Medicine, 14. https://doi.org/10.1177/20503121261455201
Vancouver
Silwal P, Pudasaini S, Magar ET. Effect of abdominal circumference on spread of intrathecal heavy bupivacaine in parturient undergoing cesarean section: An observational study. Sage Open Medicine. 2026;14. doi:10.1177/20503121261455201
BibTeX
@article{Silwal2026,
author = {Silwal, Prasant and Pudasaini, Sangita and Magar, Elisha Thapa},
title = {Effect of abdominal circumference on spread of intrathecal heavy bupivacaine in parturient undergoing cesarean section: An observational study},
journal = {Sage Open Medicine},
year = {2026},
volume = {14},
doi = {10.1177/20503121261455201}
}