EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Reliability and standard error of measurement of pressure pain thresholds at articular landmarks

Fabian Tomschi iD, Thomas Hilberg iD

British Journal of Pain · 24.06.2026

DOI: 10.1177/20494637261463704 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Pain, online erschienen am 24.06.2026. Verfasst von Fabian Tomschi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Medicine, University of Wuppertal, Wuppertal, Germany. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pressure pain threshold (PPT) testing is a widely used quantitative sensory testing method to assess mechanical pain sensitivity. While reference values for PPT at articular-/joint-related and osseous landmarks are available, data on measurement reliability remain limited. This study aimed to determine the intra- and inter-rater reliability of PPT measurements and to report the standard error of measurement (SEM) for joint PPT.

Methods

Healthy participants aged 18–40 years were included in a two-part study. In Part A ( N = 40), intra-rater reliability was assessed through three repeated PPT measurements by the same examiner. In Part B ( N = 40), inter-rater reliability was evaluated with two different examiners. PPT was measured at joints (elbow, knee, ankle) and reference landmarks (sternum, forehead) using a digital algometer. ICCs (2,k model) and SEM were calculated for each landmark.

Results

Intra-rater reliability was excellent at all landmarks (ICCs ≥ 0.926) except the elbow with a good reliability (ICC = 0.848). Inter-rater reliability was excellent at the sternum (ICC = 0.950) and good at the ankle, knee, elbow, and forehead (ICCs ≥ 0.813). SEM values varied across landmarks, with lowest values observed at reference landmarks sites (e.g., sternum and forehead). ICCs are similar between sexes.

Conclusions

PPT measurements at articular (joints) and bony reference landmarks show good to excellent reliability. These findings support the use of joint PPT in standardized pain sensitivity assessments and provide a basis for clinical and research applications. However, findings are limited to pain-free participants and should be replicated in broader populations.

Schlagwörter

Stichwörter der Autor:innen

intra-class correlation coefficientpain measurementpain sensitivitypressure pain thresholdreliability

Autor:innen und Institutionen

  • Department of Sports Medicine, University of Wuppertal, Wuppertal, Germany.

ORCID-Profile: Fabian Tomschi, Thomas Hilberg

Zitieren

APA

Tomschi, F., & Hilberg, T. (2026). Reliability and standard error of measurement of pressure pain thresholds at articular landmarks. British Journal of Pain. https://doi.org/10.1177/20494637261463704

Vancouver

Tomschi F, Hilberg T. Reliability and standard error of measurement of pressure pain thresholds at articular landmarks. British Journal of Pain. 2026. doi:10.1177/20494637261463704

BibTeX
@article{Tomschi2026,
  author = {Tomschi, Fabian and Hilberg, Thomas},
  title = {Reliability and standard error of measurement of pressure pain thresholds at articular landmarks},
  journal = {British Journal of Pain},
  year = {2026},
  doi = {10.1177/20494637261463704}
}
Kostenlos starten →