EUVIMEDEUVIMED entdecken
Open Access

Diagnostic performance of virtual fractional flow reserve derived from routine coronary angiography using segmentation free reduced order (1-dimensional) flow modelling

Kevin Mohee iD, Jonathan P Mynard, Gauravsingh Dhunnoo, Rhodri Davies, Perumal Nithiarasu, Julian P Halcox, Daniel R Obaid

JRSM Cardiovascular Disease · 2020-01 · 9

DOI: 10.1177/2048004020967578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JRSM Cardiovascular Disease, online erschienen am 05.11.2020. Verfasst von Kevin Mohee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Swansea Bay University Health Board, Morriston Hospital, Swansea, UK. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Fractional flow reserve (FFR) improves assessment of the physiological significance of coronary lesions compared with conventional angiography. However, it is an invasive investigation. We tested the performance of a virtual FFR (1D-vFFR) using routine angiographic images and a rapidly performed reduced order computational model.

Methods

Quantitative coronary angiography (QCA) was performed in 102 with coronary lesions assessed by invasive FFR. A 1D-vFFR for each lesion was created using reduced order (one-dimensional) computational flow modelling derived from conventional angiographic images and patient specific estimates of coronary flow. The diagnostic accuracy of 1D-vFFR and QCA derived stenosis was compared against the gold standard of invasive FFR using area under the receiver operator characteristic curve (AUC).

Results

QCA revealed the mean coronary stenosis diameter was 44% ± 12% and lesion length 13 ± 7 mm. Following angiography calculation of the 1DvFFR took less than one minute. Coronary stenosis (QCA) had a significant but weak correlation with FFR (r = −0.2, p = 0.04) and poor diagnostic performance to identify lesions with FFR

Schlagwörter

Stichwörter der Autor:innen

Coronary imaging: angiography/ultrasound/Doppler/CCcardiovascular imaging agents/techniquescatheter-based coronary interventions: stents

Autor:innen und Institutionen

  • Department of Cardiology, Swansea Bay University Health Board, Morriston Hospital, Swansea, UK.
  • Heart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
  • Department of Paediatrics, The University of Melbourne, Parkville, VIC, Australia.
  • Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC, Australia.
  • Department of Cardiology, The Royal Children's Hospital, Parkville, VIC, Australia.
  • Swansea University School of Engineering, Bay Campus, Swansea, UK.

ORCID-Profile: Kevin Mohee

Zitieren

APA

Mohee, K., Mynard, J. P., Dhunnoo, G., Davies, R., Nithiarasu, P., Halcox, J. P., & Obaid, D. R. (2020). Diagnostic performance of virtual fractional flow reserve derived from routine coronary angiography using segmentation free reduced order (1-dimensional) flow modelling. JRSM Cardiovascular Disease, 9. https://doi.org/10.1177/2048004020967578

Vancouver

Mohee K, Mynard JP, Dhunnoo G, Davies R, Nithiarasu P, Halcox JP, et al. Diagnostic performance of virtual fractional flow reserve derived from routine coronary angiography using segmentation free reduced order (1-dimensional) flow modelling. JRSM Cardiovascular Disease. 2020;9. doi:10.1177/2048004020967578

BibTeX
@article{Mohee2020,
  author = {Mohee, Kevin and Mynard, Jonathan P and Dhunnoo, Gauravsingh and Davies, Rhodri and Nithiarasu, Perumal and Halcox, Julian P and Obaid, Daniel R},
  title = {Diagnostic performance of virtual fractional flow reserve derived from routine coronary angiography using segmentation free reduced order (1-dimensional) flow modelling},
  journal = {JRSM Cardiovascular Disease},
  year = {2020},
  volume = {9},
  doi = {10.1177/2048004020967578}
}
Kostenlos starten →