EUVIMEDEUVIMED entdecken
Open Access

Perfusion computed tomography relative threshold values in definition of acute stroke lesions

Radzina Maija, Krumina Gaida, Kupcs Karlis, Miglane Evija

Acta Radiologica Short Reports · 2013

DOI: 10.1177/2047981613486099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica Short Reports, 2013. Verfasst von Radzina Maija und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Riga Stradins University , Riga. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCRR NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Perfusion computed tomography (CT) is a relatively new technique that allows fast evaluation of cerebral hemodynamics by providing perfusion maps and gives confirmation of perfusion deficits in ischemic areas. Some controversies exist regarding accuracy of quantitative detection of tissue viability: penumbra (tissue at risk) or core (necrosis).

Purpose

To define brain tissue viability grade on the basis of the perfusion CT parameters in acute stroke patients. Material and Methods A multimodal CT imaging protocol; unenhanced CT of the brain, CT angiography of head and neck blood vessels, followed by brain perfusion CT and 24 h follow-up brain CT was performed. Perfusion deficits were detected first visually, with subsequent manual quantitative and relative measurements in affected and contra-lateral hemisphere in 87 acute stroke patients.

Results

Visual perfusion deficit on perfusion CT images was found in 78 cases (38 women, 40 men; mean age, 30–84 years). Penumbra lesions ( n = 49) and core lesions ( n = 42) were detected by increased mean transit time (MTT) on perfusion CT maps in comparison to contra-lateral hemispheres. Cerebral blood volume (CBV) mean values in the penumbra group were increased in the penumbra group and decreased in the core group. Cerebral blood flow (CBF) values were decreased in penumbra and markedly decreased in core lesion.

Conclusion

Perfusion CT measurements are reliable in estimation of penumbra and core lesions in acute stroke patients, if relative threshold values are used. The most accurate parameter of hypoperfusion is increased MTT above 190%. Relative threshold values for irreversible lesion are CBF

Schlagwörter

Stichwörter der Autor:innen

Computed tomographyperfusionstroke

Autor:innen und Institutionen

  • Radiology Department, Riga Stradins University , Riga.

Förderung

  • NCRR NIH HHS

Zitieren

APA

Maija, R., Gaida, K., Karlis, K., & Evija, M. (2013). Perfusion computed tomography relative threshold values in definition of acute stroke lesions. Acta Radiologica Short Reports. https://doi.org/10.1177/2047981613486099

Vancouver

Maija R, Gaida K, Karlis K, Evija M. Perfusion computed tomography relative threshold values in definition of acute stroke lesions. Acta Radiologica Short Reports. 2013. doi:10.1177/2047981613486099

BibTeX
@article{Maija2013,
  author = {Maija, Radzina and Gaida, Krumina and Karlis, Kupcs and Evija, Miglane},
  title = {Perfusion computed tomography relative threshold values in definition of acute stroke lesions},
  journal = {Acta Radiologica Short Reports},
  year = {2013},
  doi = {10.1177/2047981613486099}
}
Kostenlos starten →