EUVIMEDEUVIMED entdecken
Crossref

Effect of Replacing Inhalation Devices on Medication Adherence

Yusuf Aydemir iD, Sahinur Aycan Alkan, Damla Serçe Unat, Çağla Koç, Mustafa Buğrahan Gürbüz, Esen Sayın Gülensoy, Figen Ergür, Makbule Özlem Akbay, Yasemin Söyler, Mecit Süerdem

Journal of Aerosol Medicine and Pulmonary Drug Delivery · 2026

DOI: 10.1177/19412711261425941 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Aerosol Medicine and Pulmonary Drug Delivery, 2026. Verfasst von Yusuf Aydemir und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonology, Faculty of Medicine, Sakarya University, Sakarya, Türkiye. Hauptthemen laut MEDLINE: Asthma, Nebulizers and Vaporizers, Medication Adherence, Pulmonary Disease, Chronic Obstructive. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aim: In the treatment of respiratory diseases, the skill and adherence to inhaler device use are very important. Therefore, frequent replacements of devices that patients are accustomed to are not recommended due to concerns that it may disrupt adherence. The purpose of the study is to determine the frequency of inhaler device replacement, the reasons for replacement, and to evaluate inhaler adherence and usage skills after replacement. Materials and Methods: Patients who had been receiving inhaler treatment for at least 1 year due to chronic respiratory diseases (COPD and asthma) were consecutively included in the study. Patients’ inhaler device satisfaction, skill status, device education status, and whether their devices were changed were noted.

Results

A total of 260 patients were included in the study. Thirty-one patients (11.9%) stated that they did not receive device training, and 40 patients (15.4%) stated that they received insufficient training. Device replacement had been performed in 158 patients (60.8%). 138 (87.3%) of the patients whose devices were changed were satisfied with their new devices. The most common reason for the change was that the patient wanted the change (54/34.2%). In 45 of the patients, the change was made without any explanation (28.4%). In 27 patients (17.1%), the replacement had been made because the formulation needed to be replaced. In 17 patients (10.8%), the device had been replaced due to side effects of the old device, and in 15 patients (9.5%), the device had been replaced because they could not use the device with the correct technique. Device usage skills were found to be better in the group whose devices were replaced than in the group whose devices were not replaced. ( p = 0.04).

Conclusion

Our findings suggest that device replacement seems to be a good option for patients who are not satisfied with their device. Although frequent device replacement is not recommended, it may be useful for patients with insufficient prior education, as the new device will provide a new training opportunity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AsthmaNebulizers and VaporizersMedication AdherencePulmonary Disease, Chronic ObstructiveHumansFemaleAdministration, InhalationPatient SatisfactionMaleMiddle AgedPatient Education as TopicAgedEquipment DesignAdultAdherence Interventions

Stichwörter der Autor:innen

COPDasthmadry powder inhalerinhalation devicesmetered dose inhaler

Autor:innen und Institutionen

  • Department of Pulmonology, Faculty of Medicine, Sakarya University, Sakarya, Türkiye.
  • Department of Pulmonology,Tayfur Ata Sökmen Faculty of Medicine, Hatay Mustafa Kemal University, Hatay, Afyon, Türkiye.
  • Department of Pulmonology, Faculty of Medicine, Bakırcay University, İzmir, Türkiye.
  • Yedikule Chest Diseases and Chest Surgery Training and Research Hospital, University of Health Sciences, Istanbul, Türkiye.
  • 29 May State Hospital, Ankara, Siirt, Türkiye.
  • Department of Chest Diseases, Faculty of Medicine, Ufuk University, Ankara, Türkiye.

ORCID-Profile: Yusuf Aydemir

Zitieren

APA

Aydemir, Y., Alkan, S. A., Unat, D. S., Koç, Ç., Gürbüz, M. B., Gülensoy, E. S., Ergür, F., Akbay, M. Ö., Söyler, Y., & Süerdem, M. (2026). Effect of Replacing Inhalation Devices on Medication Adherence. Journal of Aerosol Medicine and Pulmonary Drug Delivery. https://doi.org/10.1177/19412711261425941

Vancouver

Aydemir Y, Alkan SA, Unat DS, Koç Ç, Gürbüz MB, Gülensoy ES, et al. Effect of Replacing Inhalation Devices on Medication Adherence. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2026. doi:10.1177/19412711261425941

BibTeX
@article{Aydemir2026,
  author = {Aydemir, Yusuf and Alkan, Sahinur Aycan and Unat, Damla Serçe and Koç, Çağla and Gürbüz, Mustafa Buğrahan and Gülensoy, Esen Sayın and Ergür, Figen and Akbay, Makbule Özlem and Söyler, Yasemin and Süerdem, Mecit},
  title = {Effect of Replacing Inhalation Devices on Medication Adherence},
  journal = {Journal of Aerosol Medicine and Pulmonary Drug Delivery},
  year = {2026},
  doi = {10.1177/19412711261425941}
}
Kostenlos starten →