Beobachtungsstudie in der Zeitschrift Journal of Neonatal-Perinatal Medicine, 2026. Verfasst von Maha Hassan Mohamed und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pediatrics Departments, Faculty of Medicine, Ain Shams University, Cairo, Egypt. Hauptthemen laut MEDLINE: Respiratory Distress Syndrome, Newborn, Lung. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Background
Respiratory distress (RD) is a major cause of admission to neonatal intensive care units (NICUs), highlighting the need for prompt and accurate assessment. Lung ultrasound (LUS) has emerged as a rapid, non-invasive, radiation-free tool with superior sensitivity to chest X-ray. Thoracic Fluid Content (TFC), measured via electrical cardiometry, may serve as a complementary parameter by reflecting pulmonary fluid load. Consequently, this study aimed to evaluate the predictive accuracy of TFC and LUS in determining the need for surfactant therapy or initiation of positive pressure ventilation in preterm neonates with respiratory distress. Patients and Methods In this prospective observational cohort study, 70 preterm neonates with RD were enrolled between April 2022 and April 2024 in the NICU of Ain Shams University, Cairo, Egypt. LUS and TFC were measured on day 1 and day 3 of life. Clinical outcomes, including surfactant need and escalation of ventilation, were recorded.
Results
An LUS score >5 strongly predicted surfactant need, showing 88.89% sensitivity and 86.05% specificity (AUC: 0.941; PPV: 80%; NPV: 92.5%). TFC values were higher in neonates who received surfactant, though not statistically significant ( p = 0.053). A significant positive correlation was observed between TFC and LUS scores (r = 0.311, p = 0.009).
Conclusion
LUS is a reliable predictor of surfactant need and respiratory support in preterm neonates with RD. While TFC correlates with LUS in assessing pulmonary fluid status, it alone did not independently predict clinical intervention requirements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Pediatrics Departments, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
- Diagnostic Radiology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
ORCID-Profile: Basma Mohamed Shehata, Ahmed Ashraf Okba, Hebatallah Ali Shaaban
Zitieren
APA
Mohamed, M. H., Shehata, B. M., Azaam, N. T., Khalifa, M. M., Okba, A. A., & Shaaban, H. A. (2026). Thoracic fluid content by electric cardiometry versus lung ultrasound in preterm neonates with respiratory distress: A prospective study. Journal of Neonatal-Perinatal Medicine. https://doi.org/10.1177/19345798251365199
Vancouver
Mohamed MH, Shehata BM, Azaam NT, Khalifa MM, Okba AA, Shaaban HA. Thoracic fluid content by electric cardiometry versus lung ultrasound in preterm neonates with respiratory distress: A prospective study. Journal of Neonatal-Perinatal Medicine. 2026. doi:10.1177/19345798251365199
BibTeX
@article{Mohamed2026,
author = {Mohamed, Maha Hassan and Shehata, Basma Mohamed and Azaam, Nesmahar Tarek and Khalifa, Mohamed Mahmoud and Okba, Ahmed Ashraf and Shaaban, Hebatallah Ali},
title = {Thoracic fluid content by electric cardiometry versus lung ultrasound in preterm neonates with respiratory distress: A prospective study},
journal = {Journal of Neonatal-Perinatal Medicine},
year = {2026},
doi = {10.1177/19345798251365199}
}
EUVIMED