Comparisons of Continuous Positive Airway Pressures Determined by Conventional Manual Titration in a Sleep Center, During Sleep Endoscopy, and Auto-Titration at Home
Journal of Otolaryngology - Head & Neck Surgery · 2026-07 · 55
DOI: 10.1177/19160216261468697 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Otolaryngology - Head & Neck Surgery, online erschienen am 25.07.2026. Verfasst von Yi-Chih Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary Medicine, Department of Internal Medicine, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. Hauptthemen laut MEDLINE: Continuous Positive Airway Pressure, Sleep Apnea, Obstructive, Endoscopy. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Taipei Tzu Chi Hospital.
Abstract (Originalsprache)
Importance: Drug-induced sleep endoscopy (DISE) could be valuable to determine an appropriate therapeutic pressure for obstructive sleep apnea (OSA).
Objective
The continuous positive airway pressure (CPAP) determined by DISE was regarded as equal to the conventional titrating pressure. There is no study comparing the DISE-titrating pressure and the home-based automatic CPAP (APAP) titrating pressure. This study compared the DISE-titrating pressure, conventional titrating pressure, and home-based APAP titrating pressure.
Design
Retrospective comparative cohort study.
Setting
This study was conducted in a single medical center in Taiwan.
Participants
A total of 59 participants with OSA who had 3 titrating pressures determined by DISE, conventional titration and home-based APAP titration were analyzed. Interventions or Exposures: Therapeutic CPAP pressure was determined by 3 methods: DISE, conventional titration, and home-based APAP titration. Main Outcome Measures: Home-based APAP titrating pressure was determined as 90% to 95% of APAP used at home for 2 weeks. The DISE-titrating pressure was determined manually based on direct visualization of upper airway patency during DISE examination. The conventional titrating pressure was determined manually under polysomnography (PSG) guidance in a sleep center. The correlation and difference between these 3 pressures were analyzed.
Results
The home-based APAP titrating pressure, conventional titrating pressure, and DISE-titrating pressure were 8.8, 8.1, and 8.2 cmH 2 O, respectively. Good reliability was observed in pairs between all 3 pressures. The DISE-titrating pressure and the conventional titrating pressure were lower than the home-based APAP titrating pressure. There was no difference between the DISE-titrating pressure and the conventional titrating pressure.
Conclusions
DISE could help provide a therapeutic CPAP pressure similar to the conventional titrating pressure in sleep center and APAP titrating pressure at home. Relevance: DISE could be a valuable alternative titrating method, especially in countries where PSG is expensive, time-consuming and difficult to access, and could facilitate earlier and more effective management of patients with OSA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary Medicine, Department of Internal Medicine, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan.
- School of Medicine, Tzu Chi University, Hualien, Taiwan.
- Department of Otolaryngology - Head and Neck Surgery, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan.
- Department of Research, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan.
ORCID-Profile: Wen-Lin Su, Mei-Chen Yang
Förderung
- Taipei Tzu Chi Hospital
Zitieren
APA
Huang, Y. C., Lan, C. C., Su, W. L., Kuo, I. J., Tzeng, I. S., & Yang, M. C. (2026). Comparisons of Continuous Positive Airway Pressures Determined by Conventional Manual Titration in a Sleep Center, During Sleep Endoscopy, and Auto-Titration at Home. Journal of Otolaryngology - Head & Neck Surgery, 55. https://doi.org/10.1177/19160216261468697
Vancouver
Huang YC, Lan CC, Su WL, Kuo IJ, Tzeng IS, Yang MC. Comparisons of Continuous Positive Airway Pressures Determined by Conventional Manual Titration in a Sleep Center, During Sleep Endoscopy, and Auto-Titration at Home. Journal of Otolaryngology - Head & Neck Surgery. 2026;55. doi:10.1177/19160216261468697
BibTeX
@article{Huang2026,
author = {Huang, Yi-Chih and Lan, Chou-Chin and Su, Wen-Lin and Kuo, Ian-Jiun and Tzeng, I-Shiang and Yang, Mei-Chen},
title = {Comparisons of Continuous Positive Airway Pressures Determined by Conventional Manual Titration in a Sleep Center, During Sleep Endoscopy, and Auto-Titration at Home},
journal = {Journal of Otolaryngology - Head & Neck Surgery},
year = {2026},
volume = {55},
doi = {10.1177/19160216261468697}
}
EUVIMED