Reducing Unnecessary Instruments in Tonsil Hemorrhage Trays at a Canadian Tertiary Care Center: A Quality Improvement Project
Journal of Otolaryngology - Head & Neck Surgery · 2024
DOI: 10.1177/19160216241267719 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Otolaryngology - Head & Neck Surgery, 2024. Verfasst von Kylen Van Osch und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada. Hauptthemen laut MEDLINE: Quality Improvement, Tertiary Care Centers, Tonsillectomy, Surgical Instruments. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
In the emergency department (ED), there are pre-assembled tonsillar hemorrhage trays for management of post-tonsillectomy hemorrhage and peritonsillar abscess. After use, the tray is sent to the medical device reprocessing (MDR) department for decontamination, sterilization, and re-organization, all at a significant cost to the hospital and environment.
Objective
The goal of this project was to reduce unnecessary instruments on the tonsil hemorrhage tray by 30% by 1 year and report on the associated cost and carbon dioxide (CO 2 ) emissions savings.
Methods
This quality improvement project was framed according to the Institute for Healthcare Improvement’s Model for Improvement. ED and Otolaryngology–Head & Neck Surgery staff and residents were surveyed to determine which instruments on the tonsil hemorrhage trays were used regularly. Based on results, a new tray was developed and compared to the old tray using MDR data and existing CO 2 emissions calculations.
Results
Tray optimization resulted in a total cost reduction from $1092.63 to $330.21 per tray per year, decreased processing time from 12 to 6-8 minutes per tray, and decreased CO 2 emissions from 6.11 to 2.85 kg per year for the old versus new tray, respectively. Overall, the new tray contains half the number of instruments, takes half the time to assemble, produces 50% less CO 2 emissions, and will save the hospital approximately $100,000 over 10 years.
Conclusion
Healthcare costs and environmental sustainability are collective responsibilities. Surgical and procedure tray optimization is a simple, effective, and scalable form of eco-action.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada.
- Department of Pediatric Emergency Medicine, Western University, London, ON, Canada.
ORCID-Profile: Julie E Strychowsky
Zitieren
APA
Van Osch, K., Madou, E., Belisle, S., & Strychowsky, J. E. (2024). Reducing Unnecessary Instruments in Tonsil Hemorrhage Trays at a Canadian Tertiary Care Center: A Quality Improvement Project. Journal of Otolaryngology - Head & Neck Surgery. https://doi.org/10.1177/19160216241267719
Vancouver
Van Osch K, Madou E, Belisle S, Strychowsky JE. Reducing Unnecessary Instruments in Tonsil Hemorrhage Trays at a Canadian Tertiary Care Center: A Quality Improvement Project. Journal of Otolaryngology - Head & Neck Surgery. 2024. doi:10.1177/19160216241267719
BibTeX
@article{VanOsch2024,
author = {Van Osch, Kylen and Madou, Edward and Belisle, Sheena and Strychowsky, Julie E},
title = {Reducing Unnecessary Instruments in Tonsil Hemorrhage Trays at a Canadian Tertiary Care Center: A Quality Improvement Project},
journal = {Journal of Otolaryngology - Head & Neck Surgery},
year = {2024},
doi = {10.1177/19160216241267719}
}
EUVIMED