Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone
Journal of Otolaryngology - Head & Neck Surgery · 2024
DOI: 10.1177/19160216241248669 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Otolaryngology - Head & Neck Surgery, 2024. Verfasst von Christian Menke und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Kidney, Liver and Metabolic Diseases, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Temporal Bone, Bone Screws. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Background
Minimally invasive cochlear implant surgery by using a microstereotactic frame demands solid connection to the bone. We aimed to determine the stability of commercially available orthodontic miniscrews to evaluate their feasibility for frame’s fixation. In addition, which substitute material most closely resembles the mechanical properties of the human temporal bone was evaluated.
Methods
Pull-out tests were carried out with five different types of orthodontic miniscrews in human temporal bone specimens. Furthermore, short fiber filled epoxy (SFFE), solid rigid polyurethane (SRPU50), bovine femur, and porcine iliac bone were evaluated as substitute materials. In total, 57 tests in human specimens and 180 tests in the substitute materials were performed.
Results
In human temporal bone, average pull-out forces ranged from 220 N to 285 N between screws. Joint stiffness in human temporal bone ranged between 14 N/mm and 358 N/mm. Statistically significant differences between the tested screws were measured in terms of stiffness and elastic energy. One screw type failed insertion due to tip breakage. No significant differences occurred between screws in maximum pull-out force. The average pull-out values of SFFE were 14.1 N higher compared to human specimen.
Conclusion
Orthodontic miniscrews provided rigid fixation when partially inserted in human temporal bone, as evidenced by pull-out forces and joint stiffness. Average values exceeded requirements despite variations between screws. Differences in stiffness and elastic energy indicate screw-specific interface mechanics. With proper insertion, orthodontic miniscrews appear suitable for microstereotactic frame anchoring during minimally invasive cochlear implant surgery. However, testing under more complex loading is needed to better predict clinical performance. For further pull-out tests, the most suitable substitute material is SFFE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Kidney, Liver and Metabolic Diseases, Hannover Medical School, Hannover, Germany.
- Otojig GmbH, Hannover, Germany.
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany.
- Department of Otolaryngology and Cluster of Excellence, "Hearing4all," Hannover Medical School, Hannover, Germany.
- Department of Otolaryngology, Medizincampus Wolfsburg der Universitätsmedizin Göttingen, Wolfsburg, Germany.
ORCID-Profile: Christian Menke, Thomas S Rau
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Menke, C., Kluge, M., Welke, B., Lenarz, T., Majdani, O., & S Rau, T. (2024). Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone. Journal of Otolaryngology - Head & Neck Surgery. https://doi.org/10.1177/19160216241248669
Vancouver
Menke C, Kluge M, Welke B, Lenarz T, Majdani O, S Rau T. Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone. Journal of Otolaryngology - Head & Neck Surgery. 2024. doi:10.1177/19160216241248669
BibTeX
@article{Menke2024,
author = {Menke, Christian and Kluge, Marcel and Welke, Bastian and Lenarz, Thomas and Majdani, Omid and S Rau, Thomas},
title = {Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone},
journal = {Journal of Otolaryngology - Head & Neck Surgery},
year = {2024},
doi = {10.1177/19160216241248669}
}
EUVIMED