EUVIMEDEUVIMED entdecken
Open Access

Strategies for enumeration of circulating microvesicles on a conventional flow cytometer

Mohammad J Alkhatatbeh, Anoop K Enjeti, Sara Baqar, Elif I Ekinci, Dorothy Liu, Rick F Thorne, Lisa F Lincz iD

Journal of Circulating Biomarkers · 2018

DOI: 10.1177/1849454418766966 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Circulating Biomarkers, 2018. Verfasst von Mohammad J Alkhatatbeh und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Jordan University of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Enumeration of circulating microvesicles (MVs) by conventional flow cytometry is accomplished by the addition of a known amount of counting beads and calculated from the formula: MV/μl = (MV count/bead count) × final bead concentration. We sought to optimize each variable in the equation by determining the best parameters for detecting 'MV count' and examining the effects of different bead preparations and concentrations on the final calculation. Three commercially available bead preparations (TruCount, Flow-Count and CountBright) were tested, and MV detection on a BD FACSCanto was optimized for gating by either forward scatter (FSC) or side scatter (SSC); the results were compared by calculating different subsets of MV on a series of 74 typical patient plasma samples. The relationship between the number of beads added to each test and the number of beads counted by flow cytometry remained linear over a wide range of bead concentrations (R2 ≥ 0.997). However, TruCount beads produced the most consistent (concentration variation = 3.8%) calculated numbers of plasma CD41+/Annexin V+ MV, which were significantly higher from that calculated using either Flow-Count or CountBright (p < 0.001). The FACSCanto was able to resolve 0.5 μm beads by FSC and 0.16 μm beads by SSC, but there were significantly more background events using SSC compared with FSC (3113 vs. 470; p = 0.008). In general, sample analysis by SSC resulted in significantly higher numbers of MV (p < 0.0001) but was well correlated with enumeration by FSC for all MV subtypes (ρ = 0.62-0.89, p < 0.0001). We conclude that all counting beads provided linear results at concentrations ranging from 6 beads/μl to 100 beads/μl, but TruCount was the most consistent. Using SSC to gate MV events produced high background which negatively affected counting bead enumeration and overall MV calculations. Strategies to reduce SSC background should be employed in order to reliably use this technique.

Schlagwörter

Stichwörter der Autor:innen

Flow cytometryabsolute countingextracellular vesiclesmicroparticlesmicrovesiclescattersubmicron particles

Autor:innen und Institutionen

  • Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan.
  • Haematology Unit, Calvary Mater Newcastle, New South Wales, Australia.
  • Hunter Medical Research Institute, New Lambton, New South Wales, Australia.
  • Faculty of Health and Medicine, University of Newcastle, New South Wales, Australia.
  • Pathology North Hunter, NSW Health Pathology, New South Wales, Australia.
  • Department of Endocrinology, Austin Health, Victoria, Australia.

ORCID-Profile: Lisa F Lincz

Förderung

  • Jordan University of Science and Technology

Zitieren

APA

Alkhatatbeh, M. J., Enjeti, A. K., Baqar, S., Ekinci, E. I., Liu, D., Thorne, R. F., & Lincz, L. F. (2018). Strategies for enumeration of circulating microvesicles on a conventional flow cytometer. Journal of Circulating Biomarkers. https://doi.org/10.1177/1849454418766966

Vancouver

Alkhatatbeh MJ, Enjeti AK, Baqar S, Ekinci EI, Liu D, Thorne RF, et al. Strategies for enumeration of circulating microvesicles on a conventional flow cytometer. Journal of Circulating Biomarkers. 2018. doi:10.1177/1849454418766966

BibTeX
@article{Alkhatatbeh2018,
  author = {Alkhatatbeh, Mohammad J and Enjeti, Anoop K and Baqar, Sara and Ekinci, Elif I and Liu, Dorothy and Thorne, Rick F and Lincz, Lisa F},
  title = {Strategies for enumeration of circulating microvesicles on a conventional flow cytometer},
  journal = {Journal of Circulating Biomarkers},
  year = {2018},
  doi = {10.1177/1849454418766966}
}
Kostenlos starten →