Symptom-based assessment during prolonged low-concentration atomization of hypochlorous acid in occupied hospital rooms: A controlled pilot study
Journal of Infection Prevention · 2026-11 · 27 (6) · 285-290
DOI: 10.1177/17571774261493083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Infection Prevention, online erschienen am 25.09.2026. Verfasst von Mikio Takahashi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Medicine, Iwate Medical University, Morioka, Japan. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Information on health effects during prolonged low-concentration atomization of hypochlorous acid in occupied hospital rooms is limited.
Methods
We conducted a single-centre controlled pilot study in occupied four-bed hospital rooms. Rooms were assigned non-randomly to atomization with hypochlorous acid solution (24 enrolled patients) or tap water (16 enrolled patients). Participants and nurses conducting the symptom assessments were blinded to the atomized solution. Atomization was performed for 12 h/day over a 30-day room-level intervention period, with a target airborne available chlorine concentration of 0.02 ppm. Prespecified symptoms were assessed daily using patient self-reports and nurse observations. No objective respiratory, physiological, or toxicological measurements were performed.
Results
One participant in each group died during the study period; both deaths were assessed by the investigator as unrelated to the assigned atomization intervention. The remaining 23 participants in the hypochlorous acid group and 15 in the tap-water group completed the 30-day observation period and were included in the final analysis. The measured airborne available chlorine concentration ranged from 0.02 to 0.04 ppm, with an average of approximately 0.03 ppm. No prespecified symptoms were reported by participants or observed by nurses in either group.
Discussion
Under the specific conditions evaluated, no prespecified symptoms were reported or observed. However, the small sample size and absence of objective respiratory, physiological, and toxicological assessments preclude conclusions regarding safety. The study did not evaluate airborne viral concentrations, infection rates, or clinical effectiveness.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Medicine, Iwate Medical University, Morioka, Japan.
ORCID-Profile: Mikio Takahashi
Zitieren
APA
Takahashi, M., & Shimooki, O. (2026). Symptom-based assessment during prolonged low-concentration atomization of hypochlorous acid in occupied hospital rooms: A controlled pilot study. Journal of Infection Prevention, 27(6), 285-290. https://doi.org/10.1177/17571774261493083
Vancouver
Takahashi M, Shimooki O. Symptom-based assessment during prolonged low-concentration atomization of hypochlorous acid in occupied hospital rooms: A controlled pilot study. Journal of Infection Prevention. 2026;27(6):285-290. doi:10.1177/17571774261493083
BibTeX
@article{Takahashi2026,
author = {Takahashi, Mikio and Shimooki, Osamu},
title = {Symptom-based assessment during prolonged low-concentration atomization of hypochlorous acid in occupied hospital rooms: A controlled pilot study},
journal = {Journal of Infection Prevention},
year = {2026},
volume = {27},
number = {6},
pages = {285--290},
doi = {10.1177/17571774261493083}
}