Guidewire–bile duct angle as a determinant of stent delivery success in EUS-guided hepaticogastrostomy: a prospective double-lumen dilator cohort with propensity score-matched historical controls
Therapeutic Advances in Gastroenterology · 2026-07 · 19
DOI: 10.1177/17562848261470177 ↗Kurz gefasst
Fachartikel in der Zeitschrift Therapeutic Advances in Gastroenterology, online erschienen am 30.07.2026. Verfasst von Naoto Aoyama und 15 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsukishi, Osaka, Japan. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Failure of stent delivery remains a major technical limitation of endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), often necessitating additional tract dilation and increasing procedural complexity and cost.
Objectives
The aim of this study was to evaluate whether the guidewire–bile duct angle is associated with stent delivery success in EUS-HGS, and to explore whether a double-lumen dilator (DLD) is associated with procedural improvement consistent with an angle-mediated mechanism rather than direct mechanical advantage.
Design
Prospective observational study with a propensity score-matched historical control.
Methods
This was a prospective single-arm observational study of patients undergoing EUS-HGS using a DLD, compared with a propensity score-matched historical (retrospective) cohort that underwent conventional dilation. The main outcome was successful stent delivery without additional tract dilation.
Results
A total of 25 patients in the DLD group were compared with 25 matched controls. Successful stent delivery without additional dilation was significantly higher in the DLD group than in the conventional group (92% vs 48%, p = 0.001). The guidewire–bile duct angle measured immediately before stent delivery-system insertion was significantly larger in the DLD group than in the conventional group (153.4° vs 123.3°, p < 0.001). On multivariable analysis, a larger guidewire–bile duct angle remained independently associated with successful stent delivery without additional tract dilation (odds ratio per 10-degree increase, 5.49; 95% confidence interval, 2.79–10.83; p < 0.001), whereas DLD use itself was not independently associated with success after adjustment for angle. Device-related costs were lower in the DLD group due to reduced need for additional dilation. The guidewire–bile duct angle showed excellent apparent discrimination in this cohort, with an exploratory threshold of 126° (AUC 0.969), requiring external validation before clinical implementation.
Conclusion
In conclusion, the improvement associated with DLD use was consistent with an angle-mediated mechanism rather than a direct effect of dilation force; these findings should be regarded as hypothesis-generating mechanistic evidence rather than mechanistic proof.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsukishi, Osaka, Japan.
- Pancreatobiliary Advanced Medical Center, Endoscopy Center, Osaka Medical and Pharmaceutical University Hospital, 2-7 Daigakuchou, Takatsukishi, Osaka 569-8686, Japan.
- Endoscopy Center, Osaka Medical and Pharmaceutical University Hospital, Takatsukishi, Osaka, Japan.
- Pancreatobiliary Advanced Medical Center, Osaka Medical and Pharmaceutical University Hospital, Takatsukishi, Osaka, Japan.
- Gastroenterology, Trong Nam Cancer Hospital, Ha Noi, Viet Nam.
- Gastroenterology, Calmette Hospital, Phnom Penh, Cambodia.
ORCID-Profile: Takeshi Ogura
Zitieren
APA
Aoyama, N., Ogura, T., Yamamoto, Y., Ueno, S., Okuda, A., Nishioka, N., Nakamura, J., Hattori, N., Bessho, K., Kanadani, T., Trong, N. N., Chhun, L. K., Aboelezz, A. F., Liao, Y. J., Liao, S. C., & Nishikawa, H. (2026). Guidewire–bile duct angle as a determinant of stent delivery success in EUS-guided hepaticogastrostomy: a prospective double-lumen dilator cohort with propensity score-matched historical controls. Therapeutic Advances in Gastroenterology, 19. https://doi.org/10.1177/17562848261470177
Vancouver
Aoyama N, Ogura T, Yamamoto Y, Ueno S, Okuda A, Nishioka N, et al. Guidewire–bile duct angle as a determinant of stent delivery success in EUS-guided hepaticogastrostomy: a prospective double-lumen dilator cohort with propensity score-matched historical controls. Therapeutic Advances in Gastroenterology. 2026;19. doi:10.1177/17562848261470177
BibTeX
@article{Aoyama2026,
author = {Aoyama, Naoto and Ogura, Takeshi and Yamamoto, Yoshitaro and Ueno, Saori and Okuda, Atsushi and Nishioka, Nobu and Nakamura, Junichi and Hattori, Nobuhiro and Bessho, Kimi and Kanadani, Takafumi and Trong, Nga Nguyen and Chhun, Ly Kim and Aboelezz, Ahmad F and Liao, Yi-Jun and Liao, Szu-Chia and Nishikawa, Hiroki},
title = {Guidewire–bile duct angle as a determinant of stent delivery success in EUS-guided hepaticogastrostomy: a prospective double-lumen dilator cohort with propensity score-matched historical controls},
journal = {Therapeutic Advances in Gastroenterology},
year = {2026},
volume = {19},
doi = {10.1177/17562848261470177}
}
EUVIMED