EUVIMEDEUVIMED entdecken
Crossref

Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)

Cengiz Akarçeşme, Elif Cengizel, Sümer Alvurdu, Emre Bağcı, Emre Altundağ, ÇağdaşÖzgür Cengizel, Ömer Şenel

Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology · 2026-03 · 240 (1) · 205-212

DOI: 10.1177/17543371241239725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, online erschienen am 09.04.2024. Verfasst von Cengiz Akarçeşme und 6 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 56 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study is to determine the reliability and validity of the IVMES H-Bord eccentric hamstring strength measurement device. Thirty-eight healthy male athletes (age: 20.9 ± 2.11 years, height: 1.79 ± 0.03 m, body weight: 76.6 kg, body mass index: 22.6 ± 0.69 kg/m 2 ) participated in this study. Each test protocol was applied in eccentric mode and isometric mode respectively. Between-session test-retest reliability of the IVMES H-Bord was analyzed for the intraclass correlation coefficient (ICC) with 95% coefficient intervals (CI). Validity of the IVMES H-Bord was examined for eccentric mode (NHT ecc ), and isometric mode (NHT iso ) using Pearson’s correlation coefficient with 95% CI and limits of agreement. Bland-Altman plots were also created to provide a representation of the agreement between two test devices. Strong correlations, good ICC values and acceptable typical errors of the estimate were observed between the NHT and isokinetic strength testing (IST) during both limbs with no proportional bias for validity analysis. In conclusion, the “IVMES H-Bord” is a reliable and valid measurement device for eccentric hamstring muscle strength and it provides important advantages for medical staff, fitness coaches and practitioners because it is portable, low cost, and field-based assessment.

Zitieren

APA

Akarçeşme, C., Cengizel, E., Alvurdu, S., Bağcı, E., Altundağ, E., Cengizel, Ç., & Şenel, Ö. (2026). Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord). Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, 240(1), 205-212. https://doi.org/10.1177/17543371241239725

Vancouver

Akarçeşme C, Cengizel E, Alvurdu S, Bağcı E, Altundağ E, Cengizel Ç, et al. Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord). Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology. 2026;240(1):205-212. doi:10.1177/17543371241239725

BibTeX
@article{Akareme2026,
  author = {Akarçeşme, Cengiz and Cengizel, Elif and Alvurdu, Sümer and Bağcı, Emre and Altundağ, Emre and Cengizel, ÇağdaşÖzgür and Şenel, Ömer},
  title = {Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology},
  year = {2026},
  volume = {240},
  number = {1},
  pages = {205--212},
  doi = {10.1177/17543371241239725}
}
Kostenlos starten →