EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Leftover aspirated material in the EBUS-TBNA suction syringe improves diagnostic yield: A prospective study

Hadas Gilboa-Sagy, David Shitrit, Elad Guber, Andy Eyre, Gali Epstein Shochet iD, Ayal Romem

Therapeutic Advances in Respiratory Disease · 2026-10 · 20

DOI: 10.1177/17534666261483936 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Therapeutic Advances in Respiratory Disease, online erschienen am 04.11.2026. Verfasst von Hadas Gilboa-Sagy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pulmonary Department, Meir Medical Center, Kfar Saba, Israel. Hauptthemen laut MEDLINE: Endoscopic Ultrasound-Guided Fine Needle Aspiration, Bronchoscopy, Lung Neoplasms. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

During endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), visible aspirated material may accumulate in the suction syringe but is typically discarded.

Objective

To assess whether cytological examination of suction-syringe aspirate improves the diagnostic performance of EBUS-TBNA.

Design

Prospective, single-center, paired-sample diagnostic study.

Methods

Pooled aspirated material was preserved in formalin and analyzed cytologically alongside routine EBUS-TBNA specimens. Diagnostic yield, adequacy, and accuracy were compared with/without syringe aspirate analysis.

Results

Among 355 screened patients, 151 (42.5%) had visible syringe aspirate and were included. Adding syringe aspirate increased diagnostic yield from 58.3% to 62.9% (+4.6%, p =0.016). Sample adequacy remained unchanged (98.7%). Accuracy for excluding malignancy improved from 85.4% to 88.1%, although not significantly (p=0.125). Concordance between TBNA and syringe samples was 87.9%. Seven diagnoses, including four malignancies, were established exclusively from syringe aspirate.

Conclusion

Cytological analysis of suction-syringe aspirate modestly but significantly enhances EBUS-TBNA diagnostic yield and should be considered in routine practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endoscopic Ultrasound-Guided Fine Needle AspirationBronchoscopyLung NeoplasmsHumansProspective StudiesSyringesFemaleMaleSuctionMiddle AgedPredictive Value of TestsAgedAdult

Stichwörter der Autor:innen

EBUS-TBNAbronchoscopycancerdiagnostic yieldsuction syringe

Autor:innen und Institutionen

  • Pulmonary Department, Meir Medical Center, Kfar Saba, Israel.
  • Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

ORCID-Profile: Gali Epstein Shochet

Zitieren

APA

Gilboa-Sagy, H., Shitrit, D., Guber, E., Eyre, A., Epstein Shochet, G., & Romem, A. (2026). Leftover aspirated material in the EBUS-TBNA suction syringe improves diagnostic yield: A prospective study. Therapeutic Advances in Respiratory Disease, 20. https://doi.org/10.1177/17534666261483936

Vancouver

Gilboa-Sagy H, Shitrit D, Guber E, Eyre A, Epstein Shochet G, Romem A. Leftover aspirated material in the EBUS-TBNA suction syringe improves diagnostic yield: A prospective study. Therapeutic Advances in Respiratory Disease. 2026;20. doi:10.1177/17534666261483936

BibTeX
@article{GilboaSagy2026,
  author = {Gilboa-Sagy, Hadas and Shitrit, David and Guber, Elad and Eyre, Andy and Epstein Shochet, Gali and Romem, Ayal},
  title = {Leftover aspirated material in the EBUS-TBNA suction syringe improves diagnostic yield: A prospective study},
  journal = {Therapeutic Advances in Respiratory Disease},
  year = {2026},
  volume = {20},
  doi = {10.1177/17534666261483936}
}
Kostenlos starten →