Impact of performance improvement strategies on unplanned extubation in an inner-city intensive care unit
Therapeutic Advances in Respiratory Disease · 2025
DOI: 10.1177/17534666251383662 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Therapeutic Advances in Respiratory Disease, 2025. Verfasst von Kriti Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care Medicine, BronxCare Health System, 1650 Grand Concourse, Bronx, NY 10457, USA. Hauptthemen laut MEDLINE: Airway Extubation, Intensive Care Units, Quality Improvement, Respiration, Artificial. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: Intensivpflege, Beatmung und Weaning
Abstract (Originalsprache)
Background
Unplanned extubation (UE) in intensive care units (ICUs) is a significant patient safety concern, associated with increased morbidity and healthcare utilization; the reported rates of UE vary from 1% to 15%. There is sparse data on the effects of multiple performance improvement (PI) strategies to decrease the rate of UE, particularly in inner-city ICU populations. This study evaluates the impact of PI strategies on UE rates and associated patient outcomes in an adult ICU.
Objectives
To determine the impact of performance improvement (PI) strategies on rates of unplanned extubation (UE), reintubation, tracheostomy, mortality, and length of hospital stay in ICU patients.
Design
Retrospective cohort study Methods: This retrospective observational study included 6,397 mechanically ventilated patients admitted to a single tertiary ICU between 2015 and 2023. Three distinct time periods were compared: Period 1 (2015–2017, pre-PI), Period 2 (2018–2020, early-PI), and Period 3 (2021–2023, sustained-PI). Demographics, sedation practices, UE characteristics, and outcomes were analyzed using logistic regression.
Results
UE incidence declined significantly from 3.79% in Period 1 to 2.17% in Period 3 ( p = 0.002). Reintubation rates dropped from 45.2% to 26.7% ( p = 0.011), and tracheostomy rates from 19.0% to 2.2% ( p < 0.001). Multivariate analysis showed reduced odds of reintubation in Periods 2 (OR = 0.219, p = 0.001) and 3 (OR = 0.345, p = 0.021) and reduced odds of tracheostomy in Period 3 (OR = 0.011, p = 0.016). Risk factors for reintubation included the absence of prior intubation history and not undergoing spontaneous breathing trials. Older age (⩾71 years) and positive urine toxicology for opiates were strongly associated with tracheostomy.
Conclusion
Implementation of PI strategies significantly reduced rates of unplanned extubation, reintubation, and tracheostomy. These findings support continued quality improvement initiatives in ICU airway management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary and Critical Care Medicine, BronxCare Health System, 1650 Grand Concourse, Bronx, NY 10457, USA.
- Affiliated With Icahn School of Medicine at Mount Sinai, New York City, NY, USA.
- Division of Pulmonary and Critical Care Medicine, BronxCare Health System, Bronx, NY, USA.
ORCID-Profile: Kriti Gupta
Zitieren
APA
Gupta, K., Espinosa, L., Penikilapate, S., Venkatram, S., & Diaz-Fuentes, G. (2025). Impact of performance improvement strategies on unplanned extubation in an inner-city intensive care unit. Therapeutic Advances in Respiratory Disease. https://doi.org/10.1177/17534666251383662
Vancouver
Gupta K, Espinosa L, Penikilapate S, Venkatram S, Diaz-Fuentes G. Impact of performance improvement strategies on unplanned extubation in an inner-city intensive care unit. Therapeutic Advances in Respiratory Disease. 2025. doi:10.1177/17534666251383662
BibTeX
@article{Gupta2025,
author = {Gupta, Kriti and Espinosa, Luis and Penikilapate, Shalini and Venkatram, Sindhaghatta and Diaz-Fuentes, Gilda},
title = {Impact of performance improvement strategies on unplanned extubation in an inner-city intensive care unit},
journal = {Therapeutic Advances in Respiratory Disease},
year = {2025},
doi = {10.1177/17534666251383662}
}
EUVIMED