Surface alterations and chondrocyte activity in articular cartilage after monopolar radiofrequency treatment
Journal of Hand Surgery (European Volume) · 06.05.2026
DOI: 10.1177/17531934261445820 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Hand Surgery (European Volume), online erschienen am 06.05.2026. Verfasst von Thomas Schmid und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, Germany. Die Arbeit nennt 50 Literaturangaben.
Abstract (Originalsprache)
Introduction
Osteoarthritis is characterized by progressive degeneration of articular cartilage and impaired joint function. Arthroscopic monopolar radiofrequency energy chondroplasty enables minimally invasive smoothing of damaged cartilage surfaces, but there are concerns about chondrocyte viability under thermal stress, which is particularly critical in the wrist because of the thin cartilage layers and complex joint anatomy.
Methods
In this in vitro study, porcine tibial plateau cartilage with simulated Outerbridge grade III degeneration was treated using six monopolar radiofrequency energy application protocols, including continuous or pulsed modes with single or double passes. Subchondral temperature was recorded, surface roughness was quantified by confocal laser scanning microscopy using the root-mean-square parameter and chondrocyte viability was assessed using live/dead and caspase 3/7 assays.
Results
Subchondral temperatures remained below physiological core body temperature in all treatment groups. All radiofrequency energy protocols resulted in a clear reduction of surface roughness compared with degenerated control cartilage. The greatest smoothing effect was observed following a single pulsed application with longer activation intervals, although this also caused extensive chondrocyte death. Shorter pulsed application intervals produced moderate surface smoothing while preserving comparatively higher chondrocyte viability.
Conclusion
Monopolar radiofrequency energy chondroplasty effectively reduces cartilage surface roughness but is associated with substantial chondrocyte loss regardless of the application protocol. Among the tested approaches, pulsed energy delivery with short activation intervals provided the most favourable balance between surface smoothing and cell preservation. However, the in vivo safety of this approach remains uncertain, particularly when applied to thin cartilage layers such as those in the wrist.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, Germany.
- Department of Trauma Surgery, Schön Clinic Munich Harlaching, Germany.
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, Germany and Mühlematt Praxis Oberwil, Switzerland.
- Department of Trauma Surgery and Emergency, University Hospital Regensburg and OTC Regensburg, Germany.
Zitieren
APA
Schmid, T., von Schmeling, M., Gehmert, S., Prantl, L., Ruewe, M., & Huber, M. (2026). Surface alterations and chondrocyte activity in articular cartilage after monopolar radiofrequency treatment. Journal of Hand Surgery (European Volume). https://doi.org/10.1177/17531934261445820
Vancouver
Schmid T, von Schmeling M, Gehmert S, Prantl L, Ruewe M, Huber M. Surface alterations and chondrocyte activity in articular cartilage after monopolar radiofrequency treatment. Journal of Hand Surgery (European Volume). 2026. doi:10.1177/17531934261445820
BibTeX
@article{Schmid2026,
author = {Schmid, Thomas and von Schmeling, Max and Gehmert, Sebastian and Prantl, Lukas and Ruewe, Marc and Huber, Michaela},
title = {Surface alterations and chondrocyte activity in articular cartilage after monopolar radiofrequency treatment},
journal = {Journal of Hand Surgery (European Volume)},
year = {2026},
doi = {10.1177/17531934261445820}
}
EUVIMED