A cadaveric feasibility study of modified contralateral C7 transfer permitting ulnar nerve recovery by lateral antebrachial cutaneous nerve
Journal of Hand Surgery (European Volume) · 2026
DOI: 10.1177/17531934251356901 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Hand Surgery (European Volume), 2026. Verfasst von Xi Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Huashan Hospital, Fudan University, P. R. China. Hauptthemen laut MEDLINE: Nerve Transfer, Ulnar Nerve. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Traditional contralateral seventh cervical nerve root (C7) transfer sacrifices the recovery of ulnar nerve. This cadaveric study, done in 20 upper extremities from 10 cadavers, looks at the feasibility of using a modified contralateral C7 transfer using lateral antebrachial cutaneous nerve to allow recovery of ulnar nerve. The deep branch of ulnar nerve was preserved with ipsilateral lateral antebrachial cutaneous nerve, while the distal end of ulnar nerve with its dorsal and superficial branches was transferred to contralateral C7 nerve root and the proximal end of ulnar nerve was anastomosed to both median and musculocutaneous nerves. The ipsilateral lateral antebrachial cutaneous nerve was separated and coapted with motor branch of ulnar nerve. The distance from the midpoint of connection of medial and lateral epicondyles of humerus (interepicondylar line) to the starting point of deep branch of ulnar nerve was significantly shorter than that to the branching point of the lateral antebrachial cutaneous nerve ( p < 0.05). The differences in diameters between deep branch of ulnar nerve and main trunk and branches of lateral antebrachial cutaneous nerve were not significant ( p > 0.05). The ratio of ulnar nerve axon count to combined total axon count of musculocutaneous nerve, main trunk of lateral antebrachial cutaneous nerve and branches to deep branch of ulnar nerve were above 1:3. In conclusion, the deep branch of ulnar nerve could be restored with lateral antebrachial cutaneous nerve, while contralateral C7 was transferred to median and musculocutaneous nerves through grafts of dorsal and superficial branches of ulnar nerve.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Hand Surgery, Huashan Hospital, Fudan University, P. R. China.
- NHC Key Laboratory of Hand Reconstruction (Fudan University), P. R. China.
- Shanghai Key Laboratory of Peripheral Nerve and Microsurgery, P. R. China.
Zitieren
APA
Chen, X., Lao, J., & Rui, J. (2026). A cadaveric feasibility study of modified contralateral C7 transfer permitting ulnar nerve recovery by lateral antebrachial cutaneous nerve. Journal of Hand Surgery (European Volume). https://doi.org/10.1177/17531934251356901
Vancouver
Chen X, Lao J, Rui J. A cadaveric feasibility study of modified contralateral C7 transfer permitting ulnar nerve recovery by lateral antebrachial cutaneous nerve. Journal of Hand Surgery (European Volume). 2026. doi:10.1177/17531934251356901
BibTeX
@article{Chen2026,
author = {Chen, Xi and Lao, Jie and Rui, Jing},
title = {A cadaveric feasibility study of modified contralateral C7 transfer permitting ulnar nerve recovery by lateral antebrachial cutaneous nerve},
journal = {Journal of Hand Surgery (European Volume)},
year = {2026},
doi = {10.1177/17531934251356901}
}
EUVIMED