EUVIMEDEUVIMED entdecken
Crossref

Long-term results of the Aptis TM total distal radioulnar joint prosthesis after previous failed surgical procedures

Gregorio Martínez Villén iD, Carlos Espada Blasco, Luis Rodríguez Nogué, Elena García González

Journal of Hand Surgery (European Volume) · 2024

DOI: 10.1177/17531934231192375 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hand Surgery (European Volume), 2024. Verfasst von Gregorio Martínez Villén und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic and Traumatology (Hand and Reconstructive Surgery Unit), Miguel Servet University Hospital, Zaragoza, Spain. Hauptthemen laut MEDLINE: Joint Prosthesis, Arthroplasty, Replacement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present a prospective study with the results of ten Aptis total distal radioulnar joint replacements in patients who had one to five previous operations. The mean postoperative follow-up was 9.7 years (range 3–14.7). The mean postoperative range of motion of the wrist improved by 9° for extension, 15° for flexion, 10° for pronation and 14° for supination, achieving values equivalent to 88%, 78%, 97% and 88% of those of the non-operated hand. There were minimal changes in radial and ulnar deviations. Grip strength improved by 7 kg, pain decreased by 8 points, QuickDASH and Mayo wrist scores improved by 51 and 53 points, respectively. Two implants had radiolucency less than 1 mm. Serum titanium ion levels were slightly elevated in two patients. Three prostheses required revision surgery for heterotopic ossification, a prominent radial screw and a periprosthetic fracture. No prostheses were removed. Six patients returned to their former professional activities and four patients adapted their jobs. Level of evidence: IV

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Joint ProsthesisArthroplasty, ReplacementHumansProspective StudiesWrist JointWristRange of Motion, ArticularTreatment Outcome

Stichwörter der Autor:innen

Aptis prosthesisRadioulnar jointcomplicationsfunctionions metalslong-term follow-upradiographic outcomes

Autor:innen und Institutionen

  • Department of Orthopaedic and Traumatology (Hand and Reconstructive Surgery Unit), Miguel Servet University Hospital, Zaragoza, Spain.
  • Department of Orthopaedic and Traumatology, University Hospital Royo Villanova, Zaragoza, Spain.
  • Department of Clinical Biochemistry, Miguel Servet University Hospital, Zaragoza, Spain.

ORCID-Profile: Gregorio Martínez Villén

Zitieren

APA

Martínez Villén, G., Espada Blasco, C., Rodríguez Nogué, L., & García González, E. (2024). Long-term results of the Aptis TM total distal radioulnar joint prosthesis after previous failed surgical procedures. Journal of Hand Surgery (European Volume). https://doi.org/10.1177/17531934231192375

Vancouver

Martínez Villén G, Espada Blasco C, Rodríguez Nogué L, García González E. Long-term results of the Aptis TM total distal radioulnar joint prosthesis after previous failed surgical procedures. Journal of Hand Surgery (European Volume). 2024. doi:10.1177/17531934231192375

BibTeX
@article{MartnezVilln2024,
  author = {Martínez Villén, Gregorio and Espada Blasco, Carlos and Rodríguez Nogué, Luis and García González, Elena},
  title = {Long-term results of the Aptis TM total distal radioulnar joint prosthesis after previous failed surgical procedures},
  journal = {Journal of Hand Surgery (European Volume)},
  year = {2024},
  doi = {10.1177/17531934231192375}
}