EUVIMEDEUVIMED entdecken
Crossref

Three-dimensional carpal alignment: computer-aided CT analysis of carpal axes and normal ranges

Theresa E K Höglund, Robert M J Sippo, Eero Waris iD

Journal of Hand Surgery (European Volume) · 2023

DOI: 10.1177/17531934231160100 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hand Surgery (European Volume), 2023. Verfasst von Theresa E K Höglund und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland. Hauptthemen laut MEDLINE: Carpal Bones, Scaphoid Bone. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Assessment of carpal alignment traditionally uses carpal bone axes measured on lateral radiographs. In this study, three-dimensional axes were defined for carpal bones using segmentation and numerical modelling of CT data of 121 neutrally positioned, asymptomatic wrists. The geometric axis was used for radius, scaphoid and capitate, whereas the axis based on a line perpendicular to the articular surface was used for the other carpal bones. Normal values of radiocarpal angles in the radial coordinate and the reliability of the computer-aided analysis are reported. The mean sagittal radiocarpal angles (positive in palmar direction) were as follows: scaphoid 58° (SD 10°), lunate 0° (SD 11°), triquetrum 12° (SD 8°), trapezium 17° (SD 8°), trapezoid −10° (SD 7°), capitate −17° (SD 9°) and hamate 2° (SD 7°). The mean coronal radiocarpal angles (positive in ulnar direction) were −42° (SD 9°), −20° (SD 4°), −49° (SD 4°), −32° (SD 6°), −16° (SD 5°), 2° (SD 7°) and 8° (SD 6°), respectively. The intra-observer reliability of the measurements was excellent (mean intraclass correlations coefficient 0.98). This study provides guidelines on how to measure and quantify carpal alignment three-dimensionally, and a database for the normal values. Together, these may be useful when analysing various wrist pathologies and kinematics of the wrist.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carpal BonesScaphoid BoneHumansReference ValuesReproducibility of ResultsWrist JointBiomechanical PhenomenaTomography, X-Ray ComputedComputers

Stichwörter der Autor:innen

Alignmentcarpal anglescomputer-aidedcone-beam CTwrist

Autor:innen und Institutionen

  • Department of Hand Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
  • Mehiläinen Helsinki Hospital, Helsinki, Finland.

ORCID-Profile: Eero Waris

Zitieren

APA

Höglund, T. E. K., Sippo, R. M. J., & Waris, E. (2023). Three-dimensional carpal alignment: computer-aided CT analysis of carpal axes and normal ranges. Journal of Hand Surgery (European Volume). https://doi.org/10.1177/17531934231160100

Vancouver

Höglund TEK, Sippo RMJ, Waris E. Three-dimensional carpal alignment: computer-aided CT analysis of carpal axes and normal ranges. Journal of Hand Surgery (European Volume). 2023. doi:10.1177/17531934231160100

BibTeX
@article{Hglund2023,
  author = {Höglund, Theresa E K and Sippo, Robert M J and Waris, Eero},
  title = {Three-dimensional carpal alignment: computer-aided CT analysis of carpal axes and normal ranges},
  journal = {Journal of Hand Surgery (European Volume)},
  year = {2023},
  doi = {10.1177/17531934231160100}
}
Kostenlos starten →