Warm, ventilate, stabilize: Clinical feasibility and non-inferiority study of MINAR™ infant warmer resuscitator
Journal of the Intensive Care Society · 08.11.2026
DOI: 10.1177/17511437261497940 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Intensive Care Society, online erschienen am 08.11.2026. Verfasst von Reza Widianto Sudjud und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Hasan Sadikin General Hospital, Universitas Padjadjaran, Bandung, West Java, I…. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: universitas padjadjaran.
Abstract (Originalsprache)
Background
Effective neonatal resuscitation requires integrated thermal support, respiratory assistance, and continuous physiological monitoring. MINAR™, a locally manufactured infant warmer resuscitator developed in Indonesia, was designed to support neonatal stabilization. This study evaluated the clinical feasibility, safety, and non-inferiority of MINAR™ compared with the Dräger Resuscitaire ® .
Methods
This single-center, randomized, non-inferiority feasibility trial allocated live-born neonates requiring postnatal resuscitation or stabilization in a 1:1 ratio to MINAR™ or Dräger Resuscitaire ® . Primary outcomes included respiratory rate (RR), heart rate (HR), peripheral oxygen saturation (SpO 2 ), body temperature, Apgar score, and Downes score measured at baseline and 5, 10, 15, and 60 min. Minimum clinically important differences were predefined. Repeated-measures ANCOVA was performed to assess the potential confounding effect of baseline Downes score.
Results
Forty-eight neonates were enrolled, and 38 were included in the final analysis (MINAR™, n = 18; Dräger Resuscitaire ® , n = 20). Baseline characteristics were comparable except for a higher baseline Downes score in the Dräger group ( p = 0.004). MINAR™ demonstrated non-inferior performance across all predefined outcomes with no differences exceeding the non-inferiority margins. After adjustment for baseline respiratory distress, MINAR™ remained associated with faster improvement in oxygen saturation and greater reduction in Downes score, whereas RR, HR, body temperature, and Apgar score showed comparable longitudinal trajectories between groups. No device-related adverse events or malfunctions were observed.
Conclusions
MINAR™ demonstrated feasibility, safety, and non-inferior clinical performance compared with the Dräger Resuscitaire ® for neonatal postnatal stabilization. The observed advantages in oxygenation and respiratory distress remained independent of baseline respiratory severity, supporting further evaluation in larger multicenter randomized trials. Clinical Trial Registry: ISRCTN88734666
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Hasan Sadikin General Hospital, Universitas Padjadjaran, Bandung, West Java, Indonesia.
- Department of Anaesthesiology and Intensive Care, Universitas Padjadjaran Hospital, Sumedang, West Java, Indonesia.
- Department of Paediatrics, Bandung Kiwari General Regional Hospital, Bandung, West Java, Indonesia.
ORCID-Profile: Reza Widianto Sudjud, Jenifer Kiem Aviani
Förderung
- universitas padjadjaran
Zitieren
APA
Sudjud, R. W., Aviani, J. K., & Abdullah, L. N. (2026). Warm, ventilate, stabilize: Clinical feasibility and non-inferiority study of MINAR™ infant warmer resuscitator. Journal of the Intensive Care Society. https://doi.org/10.1177/17511437261497940
Vancouver
Sudjud RW, Aviani JK, Abdullah LN. Warm, ventilate, stabilize: Clinical feasibility and non-inferiority study of MINAR™ infant warmer resuscitator. Journal of the Intensive Care Society. 2026. doi:10.1177/17511437261497940
BibTeX
@article{Sudjud2026,
author = {Sudjud, Reza Widianto and Aviani, Jenifer Kiem and Abdullah, Lia Nazliah},
title = {Warm, ventilate, stabilize: Clinical feasibility and non-inferiority study of MINAR™ infant warmer resuscitator},
journal = {Journal of the Intensive Care Society},
year = {2026},
doi = {10.1177/17511437261497940}
}
EUVIMED