Fachartikel in der Zeitschrift Women's Health, 2025. Verfasst von Evdokia Billis und 11 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Clinical Physiotherapy and Research, Department of Physiotherapy, School of Health Rehabilitation Sciences, University of Patras, Rio, …. Hauptthemen laut MEDLINE: Pelvimetry, Physical Therapists, Pubic Symphysis Diastasis, Rectus Abdominis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultrasound imaging has become popular among physiotherapists for monitoring diastasis rectus abdominis postpartum, but its reliability requires further exploration.

Objectives

To investigate physiotherapists’ intra-tester, inter-tester, and test-retest reliability of inter-recti distance measurement utilizing real-time ultrasound across a mixed women sample.

Design

Reliability study.

Methods

Volunteers comprising nulliparous and parous women of different ages and body mass index participated. Five physiotherapists performed ultrasound measurements, following sonographic training. Four conditions were tested in supine; rest, curl-up, transversus abdominus activation, and transversus abdominus with curl-up. Three locations were randomly measured: umbilicus, 3 cm above the umbilicus, and halfway between the umbilicus and xiphoid process. For intra-tester reliability, each therapist undertook three repeated measurements. For inter-tester reliability, mean inter-recti distance measurements were explored across any two tester combinations within and across sessions. Test-retest reliability explored repeated measurements 5–8 days later. Data were analyzed with intraclass correlation coefficients 2,1 .

Results

54 women (33.2 ± 15.2 years old, body mass index: 24.2 ± 3.7), 19 (35.2%) being parous participated. Intra-tester reliability across each physiotherapist was very good (intraclass correlation coefficients = 0.677–0.989). Intra-session reliability across any two testers yielded very good results (intraclass correlation coefficients = 0.76–0.92), whereas across-session yielded good reliability (intraclass correlation coefficients >0.76) except for one condition (3 cm above umbilicus in combined transversus abdominus and curl-up). Test-retest reliability was also very good (intraclass correlation coefficients = 0.78–0.96). Significant differences in inter-recti distance were found, with parous women showing consistently larger values (p < 0.05).

Conclusion

Physiotherapists, following sonographic training, can reliably measure inter-recti distances in both nulliparous and parous women across active and resting tasks. Thus, ultrasound measurement of inter-recti distance is recommended in physiotherapy practice for monitoring diastasis rectus abdominis and assessing rehabilitation progress. However, sub-umbilical inter-recti distance measurements and the impact of co-contraction on reliability require further research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PelvimetryPhysical TherapistsPubic Symphysis DiastasisRectus AbdominisUltrasonographyAdultFemaleHumansPregnancyBody Mass IndexParityPostpartum PeriodReproducibility of ResultsObserver Variation

Stichwörter der Autor:innen

diastasis recti abdominis (DRA)inter-recti distance (IRD)reliabilityultrasound

Autor:innen und Institutionen

  • Laboratory of Clinical Physiotherapy and Research, Department of Physiotherapy, School of Health Rehabilitation Sciences, University of Patras, Rio, Greece.
  • General Hospital Asklipieio Voulas, Athens, Greece.
  • Department of Pathology, University Hospital of Patras, Rio, Greece.
  • Anatomy Department, Medical School, University of Crete, Heraklion, Greece.

ORCID-Profile: Evdokia Billis, Anastasia Skoura, Dimitra Tania Papanikolaou

Zitieren

APA

Billis, E., Skoura, A., Papakonstantinou, T. E., Papanikolaou, D. T., Tsekoura, M., Andriopoulou, M., Matzaroglou, C., Lampropoulou, S., Koumoundourou, D., Trachani, E., Bania, T., & Drakonaki, E. (2025). Physiotherapists’ reliability of inter-recti distance measurement with real-time ultrasound across a mixed women population sample. Women's Health. https://doi.org/10.1177/17455057251361999

Vancouver

Billis E, Skoura A, Papakonstantinou TE, Papanikolaou DT, Tsekoura M, Andriopoulou M, et al. Physiotherapists’ reliability of inter-recti distance measurement with real-time ultrasound across a mixed women population sample. Women's Health. 2025. doi:10.1177/17455057251361999

BibTeX
@article{Billis2025,
  author = {Billis, Evdokia and Skoura, Anastasia and Papakonstantinou, Tatiana-Elena and Papanikolaou, Dimitra Tania and Tsekoura, Maria and Andriopoulou, Maria and Matzaroglou, Charalampos and Lampropoulou, Sofia and Koumoundourou, Dimitra and Trachani, Eftichia and Bania, Theofani and Drakonaki, Elena},
  title = {Physiotherapists’ reliability of inter-recti distance measurement with real-time ultrasound across a mixed women population sample},
  journal = {Women's Health},
  year = {2025},
  doi = {10.1177/17455057251361999}
}
Kostenlos starten →