AFMD Master: An open-source software for automated extraction of artery flow-mediated dilation from vascular ultrasound videos with validation against manual analysis
Ultrasound · 2026-08 · 34 (3) · 195-201
DOI: 10.1177/1742271x261451986 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasound, online erschienen am 05.06.2026. Verfasst von Alessandro Gentilin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Université Marie et Louis Pasteur, SINERGIES, Besançon, France. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Artery flow-mediated dilation (FMD) is a non-invasive method for assessing vascular endothelial function and cardiovascular disease risk. Flow-mediated dilation is calculated as the percentage increase in arterial diameter following a post-ischemic increase in blood flow through ultrasound analysis. Manual extraction of flow-mediated dilation scores is time-consuming, operator-dependent, and prone to variability. Automated software solutions for processing ultrasound data could enhance efficiency, accuracy, standardisation, and scalability for clinical and research applications, especially when distributed as free, open-source tools accessible even to non-coders. However, no current software tools reporting these features are available for automatic flow-mediated dilation extraction.
Methods
We developed aFMD Master, a free, open-source software tool with an intuitive graphical interface designed for non-coders. The software is compatible with most of the videos from different ultrasound scanners, extracts arterial diameters, and outputs PDF reports and Excel datasheets with flow-mediated dilation scores. Validation was conducted by comparing software outputs with manually obtained data from 115 participants, using scatter plots, Bland–Altman analysis, and other appropriate statistical metrics.
Results
Strong correlation between the software and manual methods was obtained ( R ² = 0.97, p < 0.01). The Bland–Altman analysis showed minimal bias (−0.0015%), with 95% limits of agreement between −0.28% and 0.28%. The software showed high accuracy, minimal bias, and low variability, with negligible impact of errors, reflecting strong precision, consistency, and reliability.
Conclusions
Validation showed excellent agreement with manual analysis, confirming accuracy, low bias, and consistency. The aFMD Master offers an accessible and reliable solution for automated flow-mediated dilation analysis, showcasing significant potential for research and clinical applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Université Marie et Louis Pasteur, SINERGIES, Besançon, France.
- Université Marie et Louis Pasteur, Plateforme Exercice Performance Santé Innovation, Besançon, France.
- Department of Neuroscience, Biomedicine and Movement Sciences, University of Verona, Italy.
ORCID-Profile: Alessandro Gentilin, Alice Gasparini
Zitieren
APA
Gentilin, A., Gasparini, A., Tam, E., & Mourot, L. (2026). AFMD Master: An open-source software for automated extraction of artery flow-mediated dilation from vascular ultrasound videos with validation against manual analysis. Ultrasound, 34(3), 195-201. https://doi.org/10.1177/1742271x261451986
Vancouver
Gentilin A, Gasparini A, Tam E, Mourot L. AFMD Master: An open-source software for automated extraction of artery flow-mediated dilation from vascular ultrasound videos with validation against manual analysis. Ultrasound. 2026;34(3):195-201. doi:10.1177/1742271x261451986
BibTeX
@article{Gentilin2026,
author = {Gentilin, Alessandro and Gasparini, Alice and Tam, Enrico and Mourot, Laurent},
title = {AFMD Master: An open-source software for automated extraction of artery flow-mediated dilation from vascular ultrasound videos with validation against manual analysis},
journal = {Ultrasound},
year = {2026},
volume = {34},
number = {3},
pages = {195--201},
doi = {10.1177/1742271x261451986}
}
EUVIMED