An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome
Vascular · 2026
DOI: 10.1177/17085381251325652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vascular, 2026. Verfasst von Liguo Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Tianjin Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Iliac Vein, May-Thurner Syndrome, Transducers, Pressure. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aims to assess the clinical value of a novel high-precision iliac vein pressure measuring device to diagnose and treat iliac vein compression syndrome.
Methods
A total of 38 patients with clinically confirmed iliac vein compression syndrome (all lesions on the left side) were selected. The iliac vein pressure and pressure recovery time (time taken for pressure to return to resting levels) were measured in four states: rest, affected limb elevation, ankle extension and flexion, and gastrocnemius muscle compression. Bilateral comparisons and pre- and post-treatment assessments were conducted.
Results
The left iliac vein pressure in the four states (42.40 ± 16.08 mmH 2 O, 51.23 ± 17.63 mmH 2 O, 70.26 ± 25.55 mmH 2 O, and 111.47 ± 58.78 mmH 2 O) and pressure recovery time (25.57 ± 10.65 s) were significantly higher compared to the right iliac vein pressure (30.67 ± 7.46 mmH 2 O, 36.55 ± 8.59 mmH 2 O, 44.84 ± 11.17 mmH 2 O, and 52.96 ± 14.06 mmH 2 O) and recovery time (18.92 ± 21.07 s) ( p = .000). The pressure in patients with left iliac occlusion (179.07 ± 31.64 mmH 2 O) was significantly higher than in patients with stenosis (79.91 ± 33.54 mmH 2 O) ( p = .000). In eight patients who underwent intraluminal iliac venous therapy, postoperative pressure (37.29 ± 7.53 mmH 2 O, 44.74 ± 5.10 mmH 2 O, 53.76 ± 5.36 mmH 2 O, and 61.96 ± 7.27 mmH 2 O) and pressure recovery time (20.88 ± 5.67 s) significantly improved compared to preoperative measurements (50.53 ± 8.21 mmH 2 O, 60.03 ± 7.50 mmH 2 O, 96.88 ± 11.67 mmH 2 O, 177.11 ± 22.40 mmH 2 O, and 35.50 ± 6.95 s) ( p < .01). Despite improvements, postoperative left iliac pressure remained significantly higher than the right iliac pressure in different states ( p < .05). The left iliac vein pressure increased significantly during ankle extension and flexion, as well as gastrocnemius muscle compression compared to resting and elevated limb states ( p < .05).
Conclusion
The innovative high-precision iliac vein pressure measuring device enables rapid and accurate quantification of iliac vein pressure. As a functional diagnostic method, it holds considerable clinical value in diagnosing iliac vein compression syndrome and evaluating treatment efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, Tianjin Hospital, Tianjin, China.
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China.
ORCID-Profile: Liguo Liu
Zitieren
APA
Liu, L., Dai, X., Zhang, X., Huang, J., Zhao, Z., & Liu, C. (2026). An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome. Vascular. https://doi.org/10.1177/17085381251325652
Vancouver
Liu L, Dai X, Zhang X, Huang J, Zhao Z, Liu C. An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome. Vascular. 2026. doi:10.1177/17085381251325652
BibTeX
@article{Liu2026,
author = {Liu, Liguo and Dai, Xiangchen and Zhang, Xiujun and Huang, Junjie and Zhao, Ziyuan and Liu, Cunfa},
title = {An experimental study of a novel high-precision iliac vein pressure measuring device to evaluate iliac vein compression syndrome},
journal = {Vascular},
year = {2026},
doi = {10.1177/17085381251325652}
}
EUVIMED