Comaneci stent-angioplasty for the optimization of inadequately deployed flow diverter stents

Kristina Sirakova, Alexander Sirakov iD, Kristian Ninov, Krasimir Minkin, Stanimir Sirakov iD

Interventional Neuroradiology · 2026

DOI: 10.1177/15910199231184520 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interventional Neuroradiology, 2026. Verfasst von Kristina Sirakova und 4 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, UH Alexandrovska, Sofia Bulgaria. Hauptthemen laut MEDLINE: Stents, Angioplasty, Intracranial Aneurysm, Endovascular Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Purpose In endovascular procedures, inadequate deployment of a flow diverter stent is a highly concerning technical complication that can lead to acute parent vessel occlusion and ischaemic events. This study aimed to assess the off-label use of the Comaneci device in managing technical difficulties associated with flow diversion. Materials and Methods We conducted an analysis of all flow diverter procedures documented in our prospectively collected database. Our objective was to identify patients with inadequately deployed implants who underwent Comaneci stent-angioplasty. Both Comaneci 17 and Comaneci 21 devices were utilized to address and remediate technical complications related to stent deployment. We reviewed anatomical features, technical details, intraprocedural complications, as well as clinical and angiographic outcomes.

Results

Thirty-one Comaneci devices were employed to remediate 31 inadequately deployed flow diverter stents. Successful resolution of technical complications associated with flow diverter placement was achieved in all attempted cases. No clinically significant complications were attributed to the technique, and no mortality was observed during the study.

Conclusion

Technical issues arising from flow diverter stent deployment are formidable complications. Familiarity with appropriate corrective manoeuvres is essential to achieve successful outcomes. The Comaneci device can be safely and effectively incorporated into the range of techniques used to rectify inadequately deployed stents.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsAngioplastyIntracranial AneurysmEndovascular ProceduresHumansFemaleMaleMiddle AgedCerebral AngiographyAgedTreatment OutcomeOff-Label Use

Stichwörter der Autor:innen

AneurysmComaneciangioplastyflow diverter

Autor:innen und Institutionen

  • Radiology Department, UH Alexandrovska, Sofia Bulgaria.
  • Radiology Department, UH St Ivan Rilski, Sofia, Bulgaria.
  • Neurosurgery Department, UH St Ivan Rilski, Sofia, Bulgaria.

ORCID-Profile: Alexander Sirakov, Stanimir Sirakov

Zitieren

APA

Sirakova, K., Sirakov, A., Ninov, K., Minkin, K., & Sirakov, S. (2026). Comaneci stent-angioplasty for the optimization of inadequately deployed flow diverter stents. Interventional Neuroradiology. https://doi.org/10.1177/15910199231184520

Vancouver

Sirakova K, Sirakov A, Ninov K, Minkin K, Sirakov S. Comaneci stent-angioplasty for the optimization of inadequately deployed flow diverter stents. Interventional Neuroradiology. 2026. doi:10.1177/15910199231184520

BibTeX
@article{Sirakova2026,
  author = {Sirakova, Kristina and Sirakov, Alexander and Ninov, Kristian and Minkin, Krasimir and Sirakov, Stanimir},
  title = {Comaneci stent-angioplasty for the optimization of inadequately deployed flow diverter stents},
  journal = {Interventional Neuroradiology},
  year = {2026},
  doi = {10.1177/15910199231184520}
}
Kostenlos starten →