Safety and feasibility of the Wahoo Hybrid Access System, a dual-mode guide catheter, in a range of neuroendovascular procedures
Interventional Neuroradiology · 2026
DOI: 10.1177/15910199231155033 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interventional Neuroradiology, 2026. Verfasst von Michael J Waters und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery and Neuroendovascular Surgery, Prisma Health Upstate, Greenville, SC, USA. Hauptthemen laut MEDLINE: Endovascular Procedures, Embolization, Therapeutic, Intracranial Aneurysm, Catheters. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
There is a clinical need for a guide catheter with combined stability and navigability, which can be used in a biaxial system for neuroendovascular procedures in place of triaxial systems.
Objective
To assess the safety and feasibility of the Q’Apel Medical Wahoo Hybrid Access System, a dual-mode 0.072″ internal diameter guide catheter, in a range of neuroendovascular procedures.
Methods
We performed a retrospective analysis of consecutive cases from a high-volume tertiary center in which the Wahoo Hybrid Access System was used as the guide catheter. Characteristics of the patients, vascular lesions, procedure, and procedural complications were assessed.
Results
A total of 102 patients were included for analysis. Vascular lesions were in the anterior circulation in 90 of 102 (88%), and posterior circulation in 12 of 102 (12%). Eighty-four cases were ruptured or unruptured aneurysm embolization procedures, the majority being balloon-assisted coiling (42%) and flow diversion (42%). All cases, including flow diversion, were performed as a biaxial system. There were no instances of prolapse of the catheter beyond the arterial segment in which it was initially placed. The procedure was able to be performed to completion in 101 of 102 (99%) cases. Thromboembolic complications occurred in 5 of 102 (5%); causality in two cases was unrelated to the guide catheter, and three were indeterminate.
Conclusions
The Wahoo guide catheter is safe and feasible when used in a variety of neuroendovascular procedures. It can accommodate a range of devices, can be safely navigated into distal vasculature, and provides support for a range of procedures, including those which traditionally require triaxial support.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery and Neuroendovascular Surgery, Prisma Health Upstate, Greenville, SC, USA.
ORCID-Profile: Michael J Waters
Zitieren
APA
Waters, M. J., Vargas, J., Turk, A., Chaudry, I., & Turner, R. D. (2026). Safety and feasibility of the Wahoo Hybrid Access System, a dual-mode guide catheter, in a range of neuroendovascular procedures. Interventional Neuroradiology. https://doi.org/10.1177/15910199231155033
Vancouver
Waters MJ, Vargas J, Turk A, Chaudry I, Turner RD. Safety and feasibility of the Wahoo Hybrid Access System, a dual-mode guide catheter, in a range of neuroendovascular procedures. Interventional Neuroradiology. 2026. doi:10.1177/15910199231155033
BibTeX
@article{Waters2026,
author = {Waters, Michael J and Vargas, Jan and Turk, Aquilla and Chaudry, Imran and Turner, Raymond D},
title = {Safety and feasibility of the Wahoo Hybrid Access System, a dual-mode guide catheter, in a range of neuroendovascular procedures},
journal = {Interventional Neuroradiology},
year = {2026},
doi = {10.1177/15910199231155033}
}
EUVIMED