Utility of the novel guide catheter in mechanical thrombectomy for emergent large vessel occlusion stroke
Interventional Neuroradiology · 2024-06 · 30 (3) · 336-341
DOI: 10.1177/15910199221084483 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Interventional Neuroradiology, online erschienen am 31.05.2022. Verfasst von Amanda Zakeri und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, The Ohio State University Medical Center, 410 W 10th Ave., Columbus, Ohio 43210. Hauptthemen laut MEDLINE: Thrombectomy. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Schlaganfall
Abstract (Originalsprache)
Background
A number of large bore guide catheters are currently available for use in neuroendovascular surgery. This study represents a multi-institutional retrospective series of patients undergoing mechanical thrombectomy with the use of a TracStar Large Distal Platform (LDP) guide catheter and assessed its performance in vivo in 107 patients.
Objective
To review a multi-institutional initial experience with the TracStar LDP guide catheter during mechanical thrombectomy for emergent large vessel occlusion (ELVO).
Methods
A retrospective review was performed at two level one stroke centres to include all patients who underwent mechanical thrombectomy and had the TracStar LDP guide catheter used during the intervention.
Results
The TracStar LDP guide catheter was successfully used in 107 mechanical thrombectomies. In anterior circulation ELVO, the guide catheter advanced into the cavernous segment of the internal carotid artery in 62.6% (62/99) of cases. In posterior circulation cases, the guide catheter advanced to the basilar artery in 87.5% (7/8) of cases. A thrombolysis in cerebral infarction 2b or greater reperfusion was obtained in 90.7% (97/107). No complications occurred related to the TracStar LDP guide catheter. Three complications occurred with aspiration catheters including a small dissection that did not require further intervention and fracturing of the AXS Catalyst 6 catheter tip in two cases. No thromboembolic events occurred.
Conclusions
The TracStar LDP large bore guide catheter is safe and effective at navigating the tortuous vascular anatomy often encountered during mechanical thrombectomy for stroke. The flexible distal and stiffer proximal components provide a good combination of navigability and support for use in neuroendovascular interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, The Ohio State University Medical Center, 410 W 10th Ave., Columbus, Ohio 43210.
- Department of Neurosurgery, Cooper University Hospital, 1 Cooper Plaza, Camden, New Jersey 08103.
- Department of Radiology, The Ohio State University Medical Center, 410 W 10th Ave., Columbus, Ohio 43210.
- Department of Neuroendovascular Imaging and Perioperative Services, The Ohio State University Medical Center, 410 W 10th Ave., Columbus, Ohio 43210.
ORCID-Profile: Amanda Zakeri, Mark Constable
Zitieren
APA
Zakeri, A., Schreiber, C., Shah, V., VonEnde, E., Granger, J., Minnema, A. J., Constable, M., Shujaat, T., Youssef, P., Powers, C., Jankowitz, B., & Nimjee, S. M. (2024). Utility of the novel guide catheter in mechanical thrombectomy for emergent large vessel occlusion stroke. Interventional Neuroradiology, 30(3), 336-341. https://doi.org/10.1177/15910199221084483
Vancouver
Zakeri A, Schreiber C, Shah V, VonEnde E, Granger J, Minnema AJ, et al. Utility of the novel guide catheter in mechanical thrombectomy for emergent large vessel occlusion stroke. Interventional Neuroradiology. 2024;30(3):336-341. doi:10.1177/15910199221084483
BibTeX
@article{Zakeri2024,
author = {Zakeri, Amanda and Schreiber, Craig and Shah, Varun and VonEnde, Elizabeth and Granger, Jessica and Minnema, Amy J and Constable, Mark and Shujaat, Taimur and Youssef, Patrick and Powers, Ciarán and Jankowitz, Brian and Nimjee, Shahid M},
title = {Utility of the novel guide catheter in mechanical thrombectomy for emergent large vessel occlusion stroke},
journal = {Interventional Neuroradiology},
year = {2024},
volume = {30},
number = {3},
pages = {336--341},
doi = {10.1177/15910199221084483}
}
EUVIMED