Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2025. Verfasst von Mario Castillo-Sang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Cardiac Surgery, St. Elizabeth Healthcare, Edgewood, KY, USA. Hauptthemen laut MEDLINE: Mitral Valve Prolapse, Endoscopy, Mitral Valve. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

A P2 prolapse comes in all sizes, and the original description of mitral loop repair (premeasured neochords) does not account for prolapse size. This technique “blind spot” can result in residual billowing or prolapse, especially in larger leaflets. Ventricular remodeling after repair can cause neochordal pseudo-elongation that worsens this residual prolapse, leading to regurgitation. We sought to study the effect of P2 prolapse size on neochordal anchoring location on the prolapse. To account for the P2 prolapse size in loop technique, we measured this intraoperatively (edge-to-annulus distance) and anchored the neochords incrementally farther from the leaflet edge in larger prolapses. Neochordal length was measured from the flattened prolapsed leaflet edge to the papillary muscle anchoring point.

Methods

Of 180 endoscopic repairs for degenerative mitral disease, 95 involved P2 neochords and 50 were premeasured (loop technique). We studied the relationship between P2 prolapse size and leaflet neochordal anchoring in 50 P2 prolapses through surgical footage review. Echocardiography at discharge and 3 months provided immediate and short-term follow-up.

Results

All 50 repairs were successful without residual billowing or regurgitation above mild when anchoring neochords based on prolapse size. The P2 prolapses were grouped by size into 4 grades: grade 1 (3 cm, n = 7). Each prolapse grade had consistent neochordal leaflet anchoring away from the edge: grade 1 = 3 mm, grade 2 = 5 to 8 mm, grade 3 = 1 to 1.5 cm, and grade 4 = 1.5 to 2 cm.

Conclusions

Our adaptation of the loop technique to include P2 prolapse size prevents residual billowing or prolapse and prevents suboptimal leaflet anchoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve ProlapseEndoscopyMitral ValveHumansFemaleMaleMiddle AgedAgedTreatment OutcomeMitral Valve InsufficiencyEchocardiography

Stichwörter der Autor:innen

Leipzig loop techniquePTFEendoscopic mitral surgeryminimally invasive mitral surgerymitral valve repairneochordal reconstruction

Autor:innen und Institutionen

  • Department of Surgery, Division of Cardiac Surgery, St. Elizabeth Healthcare, Edgewood, KY, USA.
  • Sanatorio Finochietto, Buenos Aires, Argentina.
  • Department of Anesthesia, St. Elizabeth Healthcare, Edgewood, KY, USA.

ORCID-Profile: Mario Castillo-Sang

Zitieren

APA

Castillo-Sang, M., Rios, M., Wilkinson, T., Khan, N., Nayak, P., & Alam, M. (2025). An Endoscopic Systematic Approach to Different Size P2 Prolapses Using a Modified Loop Technique. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845251391801

Vancouver

Castillo-Sang M, Rios M, Wilkinson T, Khan N, Nayak P, Alam M. An Endoscopic Systematic Approach to Different Size P2 Prolapses Using a Modified Loop Technique. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2025. doi:10.1177/15569845251391801

BibTeX
@article{CastilloSang2025,
  author = {Castillo-Sang, Mario and Rios, Matias and Wilkinson, Thomas and Khan, Niem and Nayak, Prashant and Alam, Masroor},
  title = {An Endoscopic Systematic Approach to Different Size P2 Prolapses Using a Modified Loop Technique},
  journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
  year = {2025},
  doi = {10.1177/15569845251391801}
}
Kostenlos starten →