Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2023. Verfasst von Husam H Balkhy und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Chicago Medicine, IL, USA. Hauptthemen laut MEDLINE: Ischemic Attack, Transient, Atrial Fibrillation, Cardiac Surgical Procedures, Stroke. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Edwards Lifesciences.
Abstract (Originalsprache)
Objective
Endoaortic balloon occlusion facilitates cardioplegic arrest during minimally invasive surgery (MIS). Studies have shown endoclamping to be as safe as traditional aortic clamping. We compared outcomes and hospital costs of endoclamping versus external aortic occlusion in a large administrative database.
Methods
There were 52,882 adults undergoing eligible cardiac surgery (October 2015 to March 2020) identified in the Premier Healthcare Database. Endoclamp procedures ( n = 419) were 1:3 propensity score matched to similar procedures using external aortic occlusion ( n = 1,244). Generalized linear modeling measured differences in in-hospital complications (major adverse renal and cardiac events, including mortality, new-onset atrial fibrillation, acute kidney injury [AKI], myocardial infarction [MI], postcardiotomy syndrome, stroke/transient ischemic attack [TIA], and aortic dissection) and length of stay (LOS).
Results
The mean age was 63 years, and 53% were male ( n = 882). The majority (93%, n = 1,543) were mitral valve procedures, and 17% of procedures ( n = 285) were robot-assisted. Total hospitalization costs were not statistically significantly different between the 2 groups ($52,158 vs $49,839, P = 0.06). The median LOS was significantly shorter in the endoclamp group (incident rate ratio = 0.87, P < 0.001). Mortality, atrial fibrillation, AKI, and stroke/TIA were similar between the 2 groups. MI and postcardiotomy syndrome were lower in the endoclamp group (odds ratio [OR] = 0.14, P = 0.006, and OR = 0.27, P = 0.005). There were no aortic dissections in the endoclamp group.
Conclusions
Aortic endoclamping in MIS was associated with similar costs, shorter LOS, no dissections, and comparably low mortality and stroke rates when compared with external clamping in this hospital billing dataset. These results demonstrate the clinical safety and efficacy of endoaortic balloon clamping in a real-world setting. Further studies are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Chicago Medicine, IL, USA.
- New York University Langone Health, NY, USA.
- University of California Davis Health, Sacramento, CA, USA.
- Edwards Lifesciences, Irvine, CA, USA.
- Thomas Jefferson University Hospital, Philadelphia, PA, USA.
- University of Alabama School of Medicine, Birmingham, AL, USA.
ORCID-Profile: Husam H Balkhy, Shannon M E Murphy
Förderung
- Edwards Lifesciences
Zitieren
APA
Balkhy, H. H., Grossi, E. A., Kiaii, B., Murphy, S. M. E., Kitahara, H., Guy, T. S., & Lewis, C. (2023). Cost and Clinical Outcomes Evaluation Between the Endoaortic Balloon and External Aortic Clamp in Cardiac Surgery. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845231185311
Vancouver
Balkhy HH, Grossi EA, Kiaii B, Murphy SME, Kitahara H, Guy TS, et al. Cost and Clinical Outcomes Evaluation Between the Endoaortic Balloon and External Aortic Clamp in Cardiac Surgery. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2023. doi:10.1177/15569845231185311
BibTeX
@article{Balkhy2023,
author = {Balkhy, Husam H and Grossi, Eugene A and Kiaii, Bob and Murphy, Shannon M E and Kitahara, Hiroto and Guy, T Sloane and Lewis, Clifton},
title = {Cost and Clinical Outcomes Evaluation Between the Endoaortic Balloon and External Aortic Clamp in Cardiac Surgery},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2023},
doi = {10.1177/15569845231185311}
}
EUVIMED