Feasibility of Robotic Mitral Valve Repair Using Barbed Nonabsorbable Sutures: A Preliminary Single-Center Experience
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2023
DOI: 10.1177/15569845231174228 ↗Kurz gefasst
Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2023. Verfasst von Kellen J Round und 9 weiteren Autor:innen. Beteiligte Einrichtung: Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Cardiac Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objective
Barbed nonabsorbable sutures have been widely adopted for tissue closure in noncardiac robotic surgery to improve intraoperative efficiency. Here, we examine the profile in robotic mitral valve repair (rMVR), which utilized barbed nonabsorbable sutures. To our knowledge, this is the first report to describe clinical outcomes for rMVR with barbed nonabsorbable sutures.
Methods
A retrospective review identified 90 patients who underwent rMVR using barbed nonabsorbable sutures at our center between 2019 and 2021. The primary outcome measure was dehiscence, while other relevant outcomes included 30-day readmission and 30-day mortality.
Results
In addition to fixation of the mitral annuloplasty band, barbed nonabsorbable sutures were employed commonly in concomitant pericardiectomy closure (100.0%, 90 of 90), atriotomy closure (100.0%, 90 of 90), and left atrial appendage closure (if eligible; 98.8%, 83 of 84). One patient who underwent mitral valve annuloplasty using only barbed nonabsorbable suture required reoperation for annuloplasty ring dehiscence. Immediate postoperative ring dehiscence was not observed in any patients after the routine reinforcement of barbed nonabsorbable sutures with everting pledgeted polyester sutures, and no additional patients required reoperation for suture-related complications. Clinical signs of dehiscence were not observed after pericardiectomy, atriotomy, or left atrial appendage closure with barbed nonabsorbable sutures. The 30-day readmission rate was 3.3% (3 of 90), and 30-day mortality was 0% (0 of 90).
Conclusions
These data suggest the initial feasibility of barbed nonabsorbable sutures in robotic cardiac surgery, specifically within rMVR. Further research is necessary to explore the long-term safety and efficacy profile of such approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA.
- Department of Cardiac Surgery, Antwerp University Hospital, Edegem, Belgium.
- Section of Cardiothoracic Surgery, Department of Surgery, Yale School of Medicine, New Haven, CT, USA.
- Department of Surgery, Division of Cardiac Surgery, University of Virginia, Charlottesville, VA, USA.
- Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University, Philadelphia, PA, USA.
ORCID-Profile: Kellen J Round, Colin C Yost, Jake L Rosen, Daniella H Wong
Zitieren
APA
Round, K. J., Yost, C. C., Rosen, J. L., Haenen, F. W. N., Komlo, C. M., Wong, D. H., Mandel, J. L., Prochno, K. W., Ott, N. Y., & Guy, T. S. (2023). Feasibility of Robotic Mitral Valve Repair Using Barbed Nonabsorbable Sutures: A Preliminary Single-Center Experience. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845231174228
Vancouver
Round KJ, Yost CC, Rosen JL, Haenen FWN, Komlo CM, Wong DH, et al. Feasibility of Robotic Mitral Valve Repair Using Barbed Nonabsorbable Sutures: A Preliminary Single-Center Experience. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2023. doi:10.1177/15569845231174228
BibTeX
@article{Round2023,
author = {Round, Kellen J and Yost, Colin C and Rosen, Jake L and Haenen, Filip W N and Komlo, Caroline M and Wong, Daniella H and Mandel, Jenna L and Prochno, Kyle W and Ott, Nathan Y and Guy, T Sloane},
title = {Feasibility of Robotic Mitral Valve Repair Using Barbed Nonabsorbable Sutures: A Preliminary Single-Center Experience},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2023},
doi = {10.1177/15569845231174228}
}
EUVIMED