EUVIMEDEUVIMED entdecken
Crossref

Transthoracic Aortic Clamp Technique for Port-Only Endoscopic Robotic Mitral Surgery

Douglas A Murphy, Ryon L Arrington iD, Amalia A Jonsson, Michael E Halkos

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2023

DOI: 10.1177/15569845231172774 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2023. Verfasst von Douglas A Murphy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Robotics, Cardiac Surgical Procedures, Aortic Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Many robotic mitral surgeons utilize right thoracotomy with transthoracic clamping of the aorta, while a smaller number employ a port-only endoscopic approach with endoaortic balloon occlusion of the aorta. We present our technique for a port-only endoscopic robotic approach with transthoracic clamping.

Methods

From July 2019 through December 2022, 133 patients underwent port-only endoscopic robotic mitral surgery with transthoracic clamp aortic occlusion and antegrade cardioplegia. Perfusion was through the femoral artery in 101 patients (76%) and axillary in 32 patients (24%). Clamp technique involved placing the clamp at the mid-ascending aorta, dynamic valve testing to 90 mm aortic root pressure, and closure of the cardioplegia cannula site prior to clamp removal. Indications for clamp utilization over balloon occlusion included both balloon supply issues and aortoiliac anatomy.

Results

Mitral repair was performed in 122 patients (92.7%) and mitral valve replacement in 11 patients (8.3%). Mean aortic occlusion time was 92 ± 21.4 min. Mean time from left atrial closure to clamp removal was 8.7 (7.2 to 12.8) min. There were no injuries to the aorta or surrounding structures, mortality, strokes, or renal failure.

Conclusions

For robotic teams with endoaortic balloon capability, this technique may be useful in certain patients with aorto-iliac pathology or limited femoral artery access. Alternatively, robotic teams who employ transthoracic aortic clamping through a thoracotomy may find this technique useful to transition to a port-only endoscopic approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresRoboticsCardiac Surgical ProceduresAortic DiseasesHumansEndoscopyAortaMinimally Invasive Surgical Procedures

Stichwörter der Autor:innen

endoscopicmitralrobotictransthoracic clamp

Autor:innen und Institutionen

  • Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA.

ORCID-Profile: Ryon L Arrington

Zitieren

APA

Murphy, D. A., Arrington, R. L., Jonsson, A. A., & Halkos, M. E. (2023). Transthoracic Aortic Clamp Technique for Port-Only Endoscopic Robotic Mitral Surgery. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845231172774

Vancouver

Murphy DA, Arrington RL, Jonsson AA, Halkos ME. Transthoracic Aortic Clamp Technique for Port-Only Endoscopic Robotic Mitral Surgery. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2023. doi:10.1177/15569845231172774

BibTeX
@article{Murphy2023,
  author = {Murphy, Douglas A and Arrington, Ryon L and Jonsson, Amalia A and Halkos, Michael E},
  title = {Transthoracic Aortic Clamp Technique for Port-Only Endoscopic Robotic Mitral Surgery},
  journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
  year = {2023},
  doi = {10.1177/15569845231172774}
}
Kostenlos starten →