EUVIMEDEUVIMED entdecken
Crossref

Robot-Assisted Liver Resection With Versius ® Surgical System: COMPAR-L Prospective Study

Laura Alaimo iD, Tommaso Campagnaro, Simone Conci, Sara Boggio, Elisa Fresu, Mario De Bellis, Edoardo Poletto, Andrea Marchese, Gessica Manzini, Simone Priolo, Anna Fratucello, Stefano Landi und 4 weitere

Surgical Innovation · 2026-12 · 33 (6) · 637-650

DOI: 10.1177/15533506261442271 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Innovation, online erschienen am 13.04.2026. Verfasst von Laura Alaimo und 15 weiteren Autor:innen. Beteiligte Einrichtung: General and Hepatobiliary Surgery Unit, Department of Surgery, Dentistry, Pediatrics, and Gynecology, Azienda Ospedaliera Universitaria Integrata (AO…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Hepatectomy, Liver Neoplasms. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

While similar procedures can be performed using various robotic platforms across different surgical fields, no data exists on robotic liver resection (RLR) with the Versius ® robotic system (Cambridge Medical Robots-CMR Surgical). This study collected data on the first case series of hepatectomies using the Versius ® system.

Methods

Patients who underwent liver resection of anterolateral segments using the Versius ® system at the General and Hepatobiliary Surgery unit of the University of Verona between July and December 2024 were enrolled. Experienced surgeons in RLR performed the resections. The short-term outcomes, timing, and cost of each surgical and non-surgical phase were analyzed.

Results

Ten patients underwent robotic liver resection using the Versius ® platform for hepatocellular carcinoma (n = 2), liver metastases (n = 2), and benign lesions (n = 6) in the anterolateral segments. Eight patients had prior abdominal surgery, 2 had multiple lesions, and 6 had anatomical resections (ie, H23 n = 3, H2 n = 1, H3 n = 1, H5-subsegmentectomy n = 1). Hilar clamping was used in 5 patients, with a median total time of 30 min (IQR 15-40), median blood loss of 50.0 mL (IQR 50.0-100.0), and no intra- or post-operative complications. Median total operative time was 259.5min (IQR 183.0-347.0) with median parenchymal transection time of 83.0min (IQR 40.8-93.8). Median total cost of the procedure was €4146.5 (IQR 3608.5-4976.2), which included personnel, operating room, robotic platform, kit, and consumables costs.

Conclusions

This preliminary experience with liver resection using the Versius ® system demonstrated its feasibility and safety. To our knowledge, this is the first reported series of liver resections utilizing the Versius ® platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresHepatectomyLiver NeoplasmsHumansFemaleMaleProspective StudiesMiddle AgedAgedOperative Time

Stichwörter der Autor:innen

Versius® robotic surgical systemcomputer-assisted surgerycost analysisliver resectionnext-generation systemrobotic liver surgery

Autor:innen und Institutionen

  • General and Hepatobiliary Surgery Unit, Department of Surgery, Dentistry, Pediatrics, and Gynecology, Azienda Ospedaliera Universitaria Integrata (AOUI) - Verona, University of Verona, Verona, Italy.
  • Department of Surgery, Dentistry, Pediatrics, and Gynecology, Azienda Ospedaliera Universitaria Integrata (AOUI) - Verona, University of Verona, Verona, Italy.
  • Intensive Care and Anesthesia Unit, Azienda Ospedaliera Universitaria Integrata (AOUI) - Verona, Verona, Italy.
  • Clinical Research Unit, Azienda Ospedaliera Universitaria Integrata (AOUI) Verona, Verona, Italy.
  • Department of Management, University of Verona, Verona, Italy.
  • Azienda Ospedaliera Universitaria Integrata (AOUI) Verona, Verona, Italy.

ORCID-Profile: Laura Alaimo

Zitieren

APA

Alaimo, L., Campagnaro, T., Conci, S., Boggio, S., Fresu, E., De Bellis, M., Poletto, E., Marchese, A., Manzini, G., Priolo, S., Fratucello, A., Landi, S., Maistri, G., Leardini, C., Bravi, C. M., & Ruzzenente, A. (2026). Robot-Assisted Liver Resection With Versius ® Surgical System: COMPAR-L Prospective Study. Surgical Innovation, 33(6), 637-650. https://doi.org/10.1177/15533506261442271

Vancouver

Alaimo L, Campagnaro T, Conci S, Boggio S, Fresu E, De Bellis M, et al. Robot-Assisted Liver Resection With Versius ® Surgical System: COMPAR-L Prospective Study. Surgical Innovation. 2026;33(6):637-650. doi:10.1177/15533506261442271

BibTeX
@article{Alaimo2026,
  author = {Alaimo, Laura and Campagnaro, Tommaso and Conci, Simone and Boggio, Sara and Fresu, Elisa and De Bellis, Mario and Poletto, Edoardo and Marchese, Andrea and Manzini, Gessica and Priolo, Simone and Fratucello, Anna and Landi, Stefano and Maistri, Gianluca and Leardini, Chiara and Bravi, Callisto Marco and Ruzzenente, Andrea},
  title = {Robot-Assisted Liver Resection With Versius ® Surgical System: COMPAR-L Prospective Study},
  journal = {Surgical Innovation},
  year = {2026},
  volume = {33},
  number = {6},
  pages = {637--650},
  doi = {10.1177/15533506261442271}
}
Kostenlos starten →