Comparing the Effects of Absorbable Polyglycolic Acid-Coated Tube and Polypropylene Suture Repairs on Stricture Formation in Biliary Anastomosis
Surgical Innovation · 2025
DOI: 10.1177/15533506251407730 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Surgical Innovation, 2025. Verfasst von Osman Bulut und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, Konya Kulu State Hospital, Konya, Turkey. Hauptthemen laut MEDLINE: Polypropylenes, Anastomosis, Surgical, Polyglycolic Acid, Sutures. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Necmettin Erbakan Üniversitesi.
Abstract (Originalsprache)
Background
Our study aimed to compare the effects of repair using polypropylene suture material vs polyglycolic acid-coated (PGA) tube on the development of biliary strictures in rat common bile duct incisions.
Methods
Thirty female rats were randomly divided into three groups. A controlled defect was created in the common bile duct. In Group 1, the defect was repaired with 8/0 polyglycolic acid; in Group 2, with 8/0 polypropylene; and in Group 3, with 8/0 polyglycolide-co-lactide followed by wrapping with an absorbable polyglycolic acid mesh tube. In the second surgical step, at 3 months postoperatively, blood samples were again taken from all subjects, liver biopsies were obtained, and the repaired bile duct area was resected for histopathological evaluation. Liver biopsies obtained before bile duct repair and at 3 months after repair were compared among the groups. Anastomotic sites and proximal bile duct diameters were compared between groups at 3 months post-repair.
Results
Postoperative ALT and GGT levels were significantly higher in Group 1 rats, while ALP levels were statistically significantly lower in Group 2 rats. Epithelial hyperplasia was detected in 20% of rats in Group 3, with fewer proliferative fibroblasts and less collagen scar tissue compared with those in other groups. The Portal edema rate was significantly lower in Group 3 than in Groups 1 and 2.
Conclusions
The use of PGA –coated tubes after PGLA suturing suggests that these tubes may reduce strictures in biliary repair in rats by maintaining a wider anastomotic diameter.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of General Surgery, Konya Kulu State Hospital, Konya, Turkey.
- Department of Pathology, Necmettin Erbakan University School of Medicine, Konya, Turkey.
- Department of General Surgery Gaziantep, Gaziantep Dr. Ersin Arslan Training and Research Hospital, Gaziantep, Turkey.
- Department of General Surgery, Kayseri State Hospital, Kayseri, Turkey.
- Department of General Surgery, Necmettin Erbakan University School of Medicine, Konya, Turkey.
- Department of Biochemistry, Necmettin Erbakan University School of Medicine, Konya, Turkey.
ORCID-Profile: Mustafa Senturk
Förderung
- Necmettin Erbakan Üniversitesi
Zitieren
APA
Bulut, O., Findik, S., Celik, A., Kocamaz, A. H., Kisi, O., Varman, A., Alkan, S., Kilinc, I., & Senturk, M. (2025). Comparing the Effects of Absorbable Polyglycolic Acid-Coated Tube and Polypropylene Suture Repairs on Stricture Formation in Biliary Anastomosis. Surgical Innovation. https://doi.org/10.1177/15533506251407730
Vancouver
Bulut O, Findik S, Celik A, Kocamaz AH, Kisi O, Varman A, et al. Comparing the Effects of Absorbable Polyglycolic Acid-Coated Tube and Polypropylene Suture Repairs on Stricture Formation in Biliary Anastomosis. Surgical Innovation. 2025. doi:10.1177/15533506251407730
BibTeX
@article{Bulut2025,
author = {Bulut, Osman and Findik, Sidika and Celik, Abdulkadir and Kocamaz, Arslan Hasan and Kisi, Omer and Varman, Alper and Alkan, Selman and Kilinc, Ibrahim and Senturk, Mustafa},
title = {Comparing the Effects of Absorbable Polyglycolic Acid-Coated Tube and Polypropylene Suture Repairs on Stricture Formation in Biliary Anastomosis},
journal = {Surgical Innovation},
year = {2025},
doi = {10.1177/15533506251407730}
}
EUVIMED