EUVIMEDEUVIMED entdecken
Crossref

Optimized ‘Full Right’ Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience

Igor Monsellato iD, Teresa Gatto, Marco Palucci, Federico Sangiuolo, Mariantonietta Alagia, Fabio Giannone, Gianluca Cassese, Celeste Del Basso, Gabriela Del Angel-Millán, Fabrizio Panaro

Surgical Innovation · 2025-12 · 32 (6) · 495-501

DOI: 10.1177/15533506251374470 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Innovation, online erschienen am 26.08.2025. Verfasst von Igor Monsellato und 9 weiteren Autor:innen. Beteiligte Einrichtung: SCDU Chirurgia Generale, Oncologica, Robotica e HBP, AOUAL SS. Antonio e Biagio e Cesare Arrigo, Alessandria, Italy. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Rectal Neoplasms, Rectum. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Robotic surgery for rectal cancer offers enhanced visualization, instrument articulation, and ergonomic benefits in confined pelvic spaces. However, the effectiveness of robotic procedures depends heavily on trocar positioning and instrument layout. Conventional configurations often require intraoperative instrument swapping or camera repositioning, potentially disrupting workflow and increasing cognitive strain. To address these limitations, we implemented a standardized “full right” instrument configuration using the Da Vinci Xi system to improve ergonomic control and procedural stability.

Methods

We conducted a prospective analysis of 22 consecutive patients undergoing robotic rectal resection at a high-volume tertiary center using the full right configuration. All robotic arms and the assistant port were positioned along the patient’s right side, with the camera fixed on Arm 2 throughout the procedure. Operative, perioperative, and pathological outcomes were evaluated.

Results

The mean console time was 170 min, and the mean operative time was 192 min. No conversions or intraoperative complications occurred. No instrument collisions were observed. Estimated blood loss was minimal in all cases. The mean hospital stay was 5.2 days. All patients achieved complete (grade 3) mesorectal excision, with a mean lymph node yield of 16.4 and negative margins in every case. No major postoperative complications were reported.

Conclusions

The full right configuration for robotic rectal resection is associated with favorable short-term outcomes, improved ergonomic conditions, and stable instrument positioning. This layout supports consistent workflow across all operative phases and may reduce intraoperative cognitive load. Further validation through larger comparative studies is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresRectal NeoplasmsRectumHumansMaleFemaleMiddle AgedProspective StudiesAgedOperative TimeEquipment DesignAdultAged, 80 and over

Stichwörter der Autor:innen

instrument positionrectal cancerrectal resectionrobotic colorectal surgerytrocar position

Autor:innen und Institutionen

  • SCDU Chirurgia Generale, Oncologica, Robotica e HBP, AOUAL SS. Antonio e Biagio e Cesare Arrigo, Alessandria, Italy.
  • Università degli Studi del Piemonte Orientale, UPO, Alessandria, Italy.

ORCID-Profile: Igor Monsellato

Zitieren

APA

Monsellato, I., Gatto, T., Palucci, M., Sangiuolo, F., Alagia, M., Giannone, F., Cassese, G., Del Basso, C., Del Angel-Millán, G., & Panaro, F. (2025). Optimized ‘Full Right’ Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience. Surgical Innovation, 32(6), 495-501. https://doi.org/10.1177/15533506251374470

Vancouver

Monsellato I, Gatto T, Palucci M, Sangiuolo F, Alagia M, Giannone F, et al. Optimized ‘Full Right’ Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience. Surgical Innovation. 2025;32(6):495-501. doi:10.1177/15533506251374470

BibTeX
@article{Monsellato2025,
  author = {Monsellato, Igor and Gatto, Teresa and Palucci, Marco and Sangiuolo, Federico and Alagia, Mariantonietta and Giannone, Fabio and Cassese, Gianluca and Del Basso, Celeste and Del Angel-Millán, Gabriela and Panaro, Fabrizio},
  title = {Optimized ‘Full Right’ Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience},
  journal = {Surgical Innovation},
  year = {2025},
  volume = {32},
  number = {6},
  pages = {495--501},
  doi = {10.1177/15533506251374470}
}
Kostenlos starten →