Vergleichsstudie in der Zeitschrift Surgical Innovation, online erschienen am 08.04.2025. Verfasst von Kaan Ozkan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, School of Medicine, Gazi University, Ankara, Turkey. Hauptthemen laut MEDLINE: Suture Techniques, Corneal Stroma, Cornea. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to assess the effectiveness of an innovative intrastromal suturing technique in an experimental rabbit model, comparing it to standard interrupted suturing, loose suture, and suturing with knot exposure.

Methods

Fourteen adult male New Zealand White rabbits were included in this study. Each rabbit underwent suturing in both eyes, divided into four groups based on suturing techniques. The novel intrastromal suturing technique involved burying the entire suture material within the corneal stroma. Corneal neovascularisation (CoNV) areas were evaluated by image analysis and immune cell densities by in vivo confocal microscopy (IVCM).

Results

The intrastromal suturing group demonstrated significantly smaller CoNV areas at both 1 week and 1 month post-suturing compared to other interventional groups, indicating effective mitigation of CoNV development and progression. Moreover, this group exhibited lower immune cell densities in the superficial stromal layer and endothelial layer, suggesting a reduced inflammatory response. Both the loose suture and the knot exposure groups exhibited significant levels of CoNV and heightened immune cell densities.

Conclusion

This experimental study demonstrated effectiveness of intrastromal suturing technique in limiting CoNV and immune cell infiltration, common contributors to graft rejection and complications. Furthermore, the study revealed that loose sutures and those with exposed knots are likely to cause more severe CoNV and inflammation, compared to the traditional interrupted suturing technique and intrastromal suturing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Suture TechniquesCorneal StromaCorneaAnimalsRabbitsMaleSuturesCorneal Neovascularization

Stichwörter der Autor:innen

corneal neovascularizationimmune cell densityintrastromal suturingrabbit studystandard interrupted suturing

Autor:innen und Institutionen

  • Department of Ophthalmology, School of Medicine, Gazi University, Ankara, Turkey.
  • Department of Ophthalmology, Training and Research Hospital, Kastamonu University, Kastamonu, Turkey.
  • Department of Ophthalmology, Training and Research Hospital, Ahi Evran University, Kırşehir, Turkey.
  • Department of Ophthalmology, School of Medicine, Erzincan Binali Yildirim University, Erzincan, Turkey.

ORCID-Profile: Kaan Ozkan, Mehmet Cuneyt Ozmen

Zitieren

APA

Ozkan, K., Aydın, B., Ucgul, A. Y., Bayrakceken, K., Ozmen, M. C., & Akata, R. F. (2025). Intrastromal Suturing Technique Compared With Interrupted Corneal Suturing Technique, Loose Suture and Knot Exposure: A Comparative Rabbit Study. Surgical Innovation, 32(4), 325-333. https://doi.org/10.1177/15533506251328456

Vancouver

Ozkan K, Aydın B, Ucgul AY, Bayrakceken K, Ozmen MC, Akata RF. Intrastromal Suturing Technique Compared With Interrupted Corneal Suturing Technique, Loose Suture and Knot Exposure: A Comparative Rabbit Study. Surgical Innovation. 2025;32(4):325-333. doi:10.1177/15533506251328456

BibTeX
@article{Ozkan2025,
  author = {Ozkan, Kaan and Aydın, Bahri and Ucgul, Ahmet Yucel and Bayrakceken, Kemal and Ozmen, Mehmet Cuneyt and Akata, Rustu Fikret},
  title = {Intrastromal Suturing Technique Compared With Interrupted Corneal Suturing Technique, Loose Suture and Knot Exposure: A Comparative Rabbit Study},
  journal = {Surgical Innovation},
  year = {2025},
  volume = {32},
  number = {4},
  pages = {325--333},
  doi = {10.1177/15533506251328456}
}
Kostenlos starten →