EUVIMEDEUVIMED entdecken
Crossref

Hybrid (Digital/Water Seal) Chest Drainage System – An Innovative Device for Patients with Anticipated Air Leaks

Uyen-Thao Le iD, Nicolas Hümmler, Frank Greiser, René Tullius-Modlmeier, Marion Benitz, Bernward Passlick

Surgical Innovation · 2024

DOI: 10.1177/15533506241232618 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Innovation, 2024. Verfasst von Uyen-Thao Le und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Lung, Drainage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To date, several chest drainage systems are available, such as digital drainage systems (DDS) and traditional systems with continuous suction or water seal. However, none of these systems were yet shown to be favorable in the treatment of complex situations such as persistent air leaks or residual spaces. We present in-vitro as well as clinical data of a novel hybrid drainage system consisting of an optimized digital drainage system (ODDS) and an underwater seal drainage system (UWSD).

Methods

For in-vitro analysis, a DDS and an ODDS were connected to a pleural cavity simulator. Different air leaks were produced and data on intrapleural pressure and air flow were analyzed. Furthermore, we tested the hybrid drainage system in 10 patients with potential air leaks after pulmonary surgery.

Results

In in-vitro analysis, we could show, that with advanced pump technology, pressure fluctuations caused by the drainage system when trying to maintain a set pressure level in patients with airleaks were much smaller when using an ODDS and could even be eliminated when using a fluid collection canister with sufficient buffer capacity. This minimized air leak boosts caused by the drainage system. Optimizing the auto-pressure regulation algorithms also led to a reduced airflow through the fistula and promoted rest. Switching to a passive UWSD also reduced the amount of airflow. Clinical application of the hybrid drainage system yielded promising results.

Conclusion

The novel hybrid drainage system shows promising results in the treatment of patients with complex clinical situations such as persistent air leaks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LungDrainageHumansSuctionPleural CavityAlgorithmsChest TubesPneumonectomy

Stichwörter der Autor:innen

digital drainage systemdrainage systemoptimized digital drainage systems

Autor:innen und Institutionen

  • Department of Thoracic Surgery, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany.
  • ATMOS Medizintechnik GmbH & Co. KG, Lenzkirch, Germany.

ORCID-Profile: Uyen-Thao Le

Zitieren

APA

Le, U. T., Hümmler, N., Greiser, F., Tullius-Modlmeier, R., Benitz, M., & Passlick, B. (2024). Hybrid (Digital/Water Seal) Chest Drainage System – An Innovative Device for Patients with Anticipated Air Leaks. Surgical Innovation. https://doi.org/10.1177/15533506241232618

Vancouver

Le UT, Hümmler N, Greiser F, Tullius-Modlmeier R, Benitz M, Passlick B. Hybrid (Digital/Water Seal) Chest Drainage System – An Innovative Device for Patients with Anticipated Air Leaks. Surgical Innovation. 2024. doi:10.1177/15533506241232618

BibTeX
@article{Le2024,
  author = {Le, Uyen-Thao and Hümmler, Nicolas and Greiser, Frank and Tullius-Modlmeier, René and Benitz, Marion and Passlick, Bernward},
  title = {Hybrid (Digital/Water Seal) Chest Drainage System – An Innovative Device for Patients with Anticipated Air Leaks},
  journal = {Surgical Innovation},
  year = {2024},
  doi = {10.1177/15533506241232618}
}
Kostenlos starten →